May 6 2002
Mr Bernard P Orlan
Director Environmental Health & Safety
New York City Board of Education
28 11 Queens Plaza North
Long Island City NY 11101 4008
Re Wipe Samples for Dioxins
High School for Leadership and Public Service (M894)
ATC Project No 15 19125-0290
Dear Mr Orlan
ATC Associates Inc (ATC) is pleased to provide this report of the results of the wipe samples
for polychlorinated dibenzo p dioxins (PCDDs)and dibenzofurans (PCDFs) collected on March
16 22 and 29 2002 at the referenced location The New York City Board of Education (BOE)
requested these samples to evaluate possible contamination in the school building
SCOPE OF WORK
The samples were collected using gauze pads and hexane as a solvent The pads and solvent
were provided and samples were analyzed by Pace Analytical Services Inc (Pace) of
Minneapolis MN a laboratory expenenced in dioxin analysis The analysis was performed by
modified EPA Method 8290 using combined capillary column gas chromatography/high
resolution mass spectrometry
Wagdi Abdelshahid Industrial Hygienist of ATC s New York City office collected the
samples consistent with generally accepted industrial hygiene practices There were
inherent limitations created by constraints of time, operational and work practice
vanability, vanations in contaminant concentrations and sampling and analytical
accuracy The results of the sampling represent conditions found on the dates the samples
were collected
WIPE SAMPLING RESULTS
On each day ATC submitted three (3) wipe samples for PCDDs/PCDFs to Pace for analysis A
copy of the laboratory analysis report is provided in the Attachment Samples were taken from
areas in various parts of the building The sample area was one square meter (1 m2)
Each sample was analyzed for sixteen (16) PCDD/PCDF isomers The results for each isomer
were then converted to 2 3 7 8 tetrachloro dibenzo p dioxm (2 3 7 8 TCDD) equivalents by
multiplying by an established equivalency factor