NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 15 pages

Attachment, PCDDs & PCDFs lab report

Machine-extracted title · confidence 40%

Attachment page for PCDDs/PCDFs report, NYC-WTC file.

NYC-WTC_000295644–000295658
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analytical Services Inc 1700 Elm Street Suite 200 'ace Analytical” Minneapolis MN 55414 Phone 612 6071700 WWW pacelabs com REPORT OF CHEMICAL ANALYSES Fax 612 6076444

PROJECT PCDD/PCDF ANALYSES DATE April 5 2002

PAGE 7 REPORT NO 02 1055018

RESULTS

The results from the analyses are presented in the following

Appendix A Documentation Appendix B PCDD/PCDF Analysis Results

DISCUSSION

The recoveries of the isotopically labeled PCDD/PCDF internal standards in the sample extracts ranged from 67 117% All of the internal standard recoveries for field samples were within the target limits for this method Also since the quantifications of the native 2 3 7 8 substituted isomers were based on isotope dilution the data were automatically corrected for variation in recovery and accurate values were obtained

A laboratory method blank was prepared and analyzed with the sample batch as part of our routine quality control procedures The results found at the beginning of Appendix B show the blank to be free of PCDDs and PCDFs at the reporting limits This indicates that the sample processing procedures did not significantly impact the results of the analyses

A laboratory spike sample was also prepared with the sample batch by extracting clean wipes that had been fortified with native standard materials The results found at the end of Appendix B show that the spiked native compounds were recovered at 68 121% These results indicate a generally high degree of accuracy for these samples It should be noted that one isomer in the spike was recovered slightly below the target range for this method The affected point is flagged P on the data summary sheet

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced except in full without the written consent of Pace Analytical Services Inc

nebc CITY_21MC100_003085209

NYC-WTC_000295652

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000295652Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000312330

Attachment with PCDD/PCDF analysis identifiers for NYC-WTC samples.

Similar indexed content

NYC-WTC_000326628

Analytical lab report for PCDDs & PCDFs; city file reference.

Similar indexed content

NYC-WTC_000312350

Attachment with analytical lab report for CITY_21MC100_003046195 and related identifiers.

Similar indexed content

Compare copies and versions →