Pace Analytical Services, Inc. 1700 Elm Street, Suite 200 ’^ace Analyticar Minneapolis, MM 55414 Phone: 612.607.1700 wvvw.pacelabs.com REPORT OF: CHEMICAL ANALYSES Fax: 612.607.6444

PROJECT: PCDD/PCDF ANALYSES DATE; April 4, 2002

PAGE: 7 REPORT NO: 02-1054762

RESULTS

The results from the analyses are presented in the following:

Appendix A - Documentation Appendix B - PCDD/PCDF Analysis Results

IDISCUaSION

The recoveries of the isotopically-labeled PCDD/PCDF internal standards in the sample extract ranged from 68-112% and indicate a level of efficiency through the extraction and enrichment steps that is considered typical for this matrix. All of the internal standard recoveries were within the Method 1613 target ranges. Since the quantifications of the native 2,3,7,8-sijbstituted isomers were based on isotope dilution, the data were automatically corrected for variation in recovery and accurate values were obtained.

A laboratory method blank was prepared and analyzed with the sample batch as part of our routine quality control procedures. The results, found at the beginning of Appendix B, show the blank to be free of PCDDs and PCDFs at the reported detection limits. This indicates that the sample preparation procedures did not significantly impact the results of the field sample determinations.

A laboratory spike sample was also prepared by extracting laboratory water that had been fortified with native standard materials. Recoveries of the native compounds in the spike sample ranged from 89-111 %. These results indicate a high level of accuracy for these analyses.

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

ndac CITY_21MC100_003012801

NYC-WTC_000349000

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000349000Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →