NYC-WTC_000271375
TEM air sample analysis results for Stuyvesant High School, AHERA method, 11/9/01.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗TEM microscopy results for exterior/interior air samples at the building.
NYC-WTC_000294212–000294214OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Associates 104 East 25 Street, New York, NY 10010 Phone; (212) 353-8280 Fax: (212) 353-8306
Attn: Mr. Bernard Orlan Received: 11/8/01 9.00.00 PM N.Y.C. Board of Education 28-11 Queens Plaza North ATC Group#: 5860
Long Island City, NY 11101 Analysis Date: 11 /9/01 Fax: (212)475-4122 Phone: (212)477-8941 Project: New Stuyvesant H. S. , 345 Chambers St., NY , NY Exterior and Interior of Building and Roof
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos Non 'Asbestos Structures Sensitivity Concentration Sample Volume Analyzed Asb 0.5/1-5 5/i (S/cc) (S/mm^) (S/cc) Notes 1 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5860 -1
2 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5860 -2
3 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5860 -3
4 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5860 -4
5 1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5860 -5
6 1936.00 0.0450 0 None Delected 0 0 0.0044 <22.24 <0.0044 5860 -6
7 1944.00 0.0450 0 Nflne Detected 0 0 0.0044 <22.24 <0.0044 5860 -7
8 1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 < 0.0044 5860 -8
ROMAN PEYSAKHOV MICHAEL A. GORYCKI, Ph.D.
Analyzed by: Approved by:
Disclaimer. The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected by nor-laboratory personnel. This lab is only responsible for data reported in stnjctures/mmT This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim product endorsement by N VLAP or any other agency of the U.S. Government. This reports relates only to the samples reported above. Quality control data (including 95% confidence limits and laboratory and analysis’ accuracy and precision) is available upon request
Accredited forNVLAP PLMTEM#101187-0, NYState ELAP #10879
CITY_21MC100_003083070
NYC-WTC_000294212
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000271375
TEM air sample analysis results for Stuyvesant High School, AHERA method, 11/9/01.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000398843
Lab TEM data and asbestos results for DOE project at Stuyvesant High School, Dec 2001.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000398979
TEM asbestos analysis of exterior/interior building samples, New Stuyvesant HS, Jan 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000398774
Asbestos TEM analysis of air samples for New Stuyvesant High School, Dec 24, 2001.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000379315
TEM asbestos analysis results for 6293, New Stuyvesant HS, Jan 2002.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000380676
TEM asbestos analysis results for exterior/interior of New Stuyvesant High School building.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000379340
TEM fiber analysis by TEM for exterior/interior of building, Jan 2002.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000379405
TEM analysis results for air samples at New Stuyvesant HS exterior/interior, Jan 2002.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273589
AHERA TEM results detailing asbestos concentrations from building samples.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000379599
AHERA TEM analysis for exterior/interior building air samples; date 2/3/02.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000380715
TEM analysis results for exterior/interior air samples at New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000378743
TEM asbestos analysis data for 6142, New Stuyvesant HS, exterior/interior, Dec 2001.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000398774
Asbestos TEM analysis of air samples for New Stuyvesant High School, Dec 24, 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273148
TEM asbestos fiber analysis of air samples from New Stuyvesant High School.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000398979
TEM asbestos analysis of exterior/interior building samples, New Stuyvesant HS, Jan 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000379405
TEM analysis results for air samples at New Stuyvesant HS exterior/interior, Jan 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273698
TEM analysis results for air samples at New Stuyvesant High School exterior/interior.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294168
TEM asbestos analysis of exterior/interior air samples at New Stuyvesant High School, Nov 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM air sample analysis results for Stuyvesant High School, AHERA method, 11/9/01.
Similar indexed content
Lab TEM data and asbestos results for DOE project at Stuyvesant High School, Dec 2001.
Similar indexed content
NYC-WTC_000398979
TEM asbestos analysis of exterior/interior building samples, New Stuyvesant HS, Jan 2002.
Similar indexed content
Asbestos TEM analysis of air samples for New Stuyvesant High School, Dec 24, 2001.
Similar indexed content
NYC-WTC_000379315
TEM asbestos analysis results for 6293, New Stuyvesant HS, Jan 2002.
Similar indexed content