NYC-WTC_000270107
TEM analysis with SAED/EDS, Stuyvesant H.S., Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗TEM asbestos analysis at Stuyvesant High School, Oct 2001.
NYC-WTC_000294076OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/05/01
ASBESTOS FIBER /ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 3C, 1987
Sample Identification Analysis Parameters
Project/Site: Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No. 60062 Floors 1-10 Date Received: 10/05/01 Grid Openings Analyzed:
Project Sample No.: SHS-l>10-10/5-55 Average Grid Opening: 1Q6.QO urn
Air Volume: 1929 liters Total Area Analyzed: 0.0450 mm2
Filter Type: MCE 25 mm diam., Pore Size: 0.45 urn Analytical Sensitivity:^^^2 s2rnrT^ Effective Area: 385 mm2 Q.0Q44 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc nqm./m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0 . 0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 G 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0. 0 0 . 0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED) None detected Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by;
Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC100_003082806
NYC-WTC_000294076
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000270107
TEM analysis with SAED/EDS, Stuyvesant H.S., Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182511
Technical data sheet recording air volume and microscopic analysis parameters for sample 5609 from Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188720
Laboratory report of asbestos fiber analysis by TEM for samples collected from floors 1-10 at Stuyvesant High School.
6 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293293
TEM asbestos analysis report for Stuyvesant HS, Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294139
TEM analysis with SAED/EDS methods for Stuyvesant HS project; notes on air volume.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270121
Asbestos fiber analysis by TEM with SAED/EDS for Stuyvesant HS, Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270106
TEM analysis with SAED/EDS, Stuyvesant H.S., Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294052
TEM analysis; sample 5609; air volume and area details.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270100
TEM analysis with SAED/EDS for Stuyvesant HS, Oct 1987.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294072
TEM asbestos analysis at Stuyvesant High School, Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294058
TEM analysis; sample 5609; 0.0450 mm2 area; 0.45 µm diffraction.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270123
Asbestos fiber analysis by TEM with SAED/EDS for Stuyvesant HS, Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000270107
TEM analysis with SAED/EDS, Stuyvesant H.S., Oct 2001.
Similar indexed content
NYC-WTC_000182511
Technical data sheet recording air volume and microscopic analysis parameters for sample 5609 from Stuyvesant High School.
Similar indexed content
NYC-WTC_000188720
Laboratory report of asbestos fiber analysis by TEM for samples collected from floors 1-10 at Stuyvesant High School.
Similar indexed content
NYC-WTC_000293293
TEM asbestos analysis report for Stuyvesant HS, Oct 2001.
Similar indexed content
NYC-WTC_000294139
TEM analysis with SAED/EDS methods for Stuyvesant HS project; notes on air volume.
Similar indexed content