NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/05/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction ISAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, ERA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5609 60040 Floors 1-10 Date Received: 10/05/01 Grid Openings Analysed:__ 4
Project Sample No.: SHS-l>10-10/5-33 Average Grid Opening: 106.00 um
Alr Volume: 1343 liters Total Area Analyzed: 0.0450 mm2
Filter Type: MCE 25 mm diam., Pore Size: 0.45 urn Analytical Sensitivity: 22.2 s/mm2 Effective Area.- 385 rnni2 0.0046 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc ngm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) C 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 C 0 0.0 0,0000 N/A No Identification 0 0 0 0 G 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by; Report Reviewed by:
Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC100_003082784
NYC-WTC_000294056
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000294063
TEM asbestos analysis at Stuyvesant High School, Oct 2001.
5 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188720
Laboratory report of asbestos fiber analysis by TEM for samples collected from floors 1-10 at Stuyvesant High School.
5 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182511
Technical data sheet recording air volume and microscopic analysis parameters for sample 5609 from Stuyvesant High School.
5 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270092
Asbestos TEM analysis at Stuyvesant High School, SAED/EDS, Oct 1987.
6 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270094
TEM analysis of Stuyvesant High School samples; SAED/EDS, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270090
Asbestos fiber TEM analysis on Stuyvesant High School samples for AHERA/SAED/EDS, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270106
TEM analysis with SAED/EDS, Stuyvesant H.S., Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294052
TEM analysis; sample 5609; air volume and area details.
6 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293295
TEM asbestos analysis report for Stuyvesant HS, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270100
TEM analysis with SAED/EDS for Stuyvesant HS, Oct 1987.
6 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270117
Asbestos fiber analysis by TEM with SAED/EDS for Stuyvesant HS, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270107
TEM analysis with SAED/EDS, Stuyvesant H.S., Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000294063
TEM asbestos analysis at Stuyvesant High School, Oct 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188720
Laboratory report of asbestos fiber analysis by TEM for samples collected from floors 1-10 at Stuyvesant High School.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182511
Technical data sheet recording air volume and microscopic analysis parameters for sample 5609 from Stuyvesant High School.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270092
Asbestos TEM analysis at Stuyvesant High School, SAED/EDS, Oct 1987.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270094
TEM analysis of Stuyvesant High School samples; SAED/EDS, Oct 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270090
Asbestos fiber TEM analysis on Stuyvesant High School samples for AHERA/SAED/EDS, Oct 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000294063
TEM asbestos analysis at Stuyvesant High School, Oct 2001.
Similar indexed content
NYC-WTC_000188720
Laboratory report of asbestos fiber analysis by TEM for samples collected from floors 1-10 at Stuyvesant High School.
Similar indexed content
NYC-WTC_000182511
Technical data sheet recording air volume and microscopic analysis parameters for sample 5609 from Stuyvesant High School.