NYC-WTC_000270876
TEM asbestos analysis; exterior/interior of building, sample 9.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗TEM analysis of exterior/interior building air at New Stuyvesant H.S., Oct 2001.
NYC-WTC_000294011OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Beard of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date; 10/28/01
ASBESTOS FIBER TUSTALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selecced-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 21C, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: New Stu\v^esant H.S, 345 Chambers St., NY, NY TEM Sample No.: 5784 62393 Exterior &. Interior of Building & Roof Date Received; 10/27/01 Grid Openings Analyzed:__ 4
Project Sample No.: 8 Average Grid Opening: 106.00 um
Air Volume; 1936 liters Total Area Analyzed: 0.0450 mm2
Filter Type: MCE 25 mm diam. Pore Size: 0.45 um Analytical Sensitivity:22^2.s/mm2 Effective Area; 385 mm2 0.0044 s/cc
FIBROUS PARTICULATES 7\NALY2ED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct Struct > = 5um Struct/mm2 Struct/cc ngm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0 . 0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.oooc N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.OOOO N/A The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by.- Report Reviewed by:
Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC1OO_OO3O82733
NYC-WTC_00029401 1
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000270876
TEM asbestos analysis; exterior/interior of building, sample 9.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182597
Technical data sheet recording air volume and microscopic analysis parameters for exterior and interior samples at Stuyvesant High School.
4 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293860
Asbestos TEM analysis parameters for New Stuyvesant HS exterior/interior; Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188707
Technical report presenting transmission electron microscopy data for asbestos fiber identification on mixed interior and exterior samples.
5 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270355
TEM analysis of NSHS sample NSHS-EIR-10/11-01, exterior/interior, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270273
Asbestos TEM analysis with SAED/EDS for Stuyvesant HS, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270968
TEM asbestos analysis with SAED/EDS for New Stuyvesant HS exterior/interior, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293972
TEM analysis; exterior/interior; received 10/26/01.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293864
TEM asbestos analysis for exterior/interior of building; includes opening and area measurements; received 10/23/01.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188687
Document containing transmission electron microscopy analysis of asbestos fibers in air samples from a high school building.
6 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182603
Laboratory report detailing transmission electron microscopy analysis of air samples from Stuyvesant High School collected in October 2001.
5 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270753
TEM analysis report for New Stuyvesant High School building exterior and interior, 10/24/01.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000270876
TEM asbestos analysis; exterior/interior of building, sample 9.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182597
Technical data sheet recording air volume and microscopic analysis parameters for exterior and interior samples at Stuyvesant High School.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293860
Asbestos TEM analysis parameters for New Stuyvesant HS exterior/interior; Oct 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188707
Technical report presenting transmission electron microscopy data for asbestos fiber identification on mixed interior and exterior samples.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270355
TEM analysis of NSHS sample NSHS-EIR-10/11-01, exterior/interior, Oct 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270273
Asbestos TEM analysis with SAED/EDS for Stuyvesant HS, Oct 2001.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM asbestos analysis; exterior/interior of building, sample 9.
Similar indexed content
NYC-WTC_000182597
Technical data sheet recording air volume and microscopic analysis parameters for exterior and interior samples at Stuyvesant High School.
Similar indexed content
Asbestos TEM analysis parameters for New Stuyvesant HS exterior/interior; Oct 2001.
Similar indexed content
Technical report presenting transmission electron microscopy data for asbestos fiber identification on mixed interior and exterior samples.
Similar indexed content
NYC-WTC_000270355
TEM analysis of NSHS sample NSHS-EIR-10/11-01, exterior/interior, Oct 2001.
Similar indexed content