NYC-WTC_000292759
TEM asbestos analysis with SAED and EDS parameters for New Stuyvesant High School, received 10/28/01.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗TEM analysis of air samples at New Stuyvesant HS, exterior/interior, Oct 2001.
NYC-WTC_000293943OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document I
ATC Environmental, Inc, 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/25/01
ASBESTOS FIBER TiNALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Pinal Rule, ERA Federal Register (40 CPR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site; New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5766 - 62343 Exterior & Interior of Building & Roof Date Received: 10/25/01 Grid Openings Analyzed: 4
Project Sample No. Average Grid Opening: 106.00 um
Air Volume ;1928 nxers Total Area Analyzed; 0.0450 mm2
Filter Type: MCE 25 mm diam.. Pore Size: 0.45 um Analytical Sensitivity: 22.2 s/nim2 Effective Area ;385 rnm2 0.0044 s/cc
FIBROUS PARTICmjATES^MALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >=5um Struct/mm2 Struct/cc nqin/m3
Chrysotile Asbestos 0 0 0 0 0 0 0. 0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 C 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.oooo N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method. This laborarory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC100_003082655
NYC-WTC_000293943
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000292759
TEM asbestos analysis with SAED and EDS parameters for New Stuyvesant High School, received 10/28/01.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293948
TEM asbestos fiber analysis for New Stuyvesant High School exterior/interior, received 10/25/01.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293972
TEM analysis; exterior/interior; received 10/26/01.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270723
TEM analysis with SAED/EDS for New Stuyvesant High School, received 10/22/01.
6 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270195
TEM analysis of air samples at Stuyvesant High School; includes volume and opening.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293944
TEM analysis of air samples at New Stuyvesant HS, exterior/interior, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293770
TEM analysis incorporating SAED/EDS for building exterior/interior samples.
6 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188695
TEM laboratory report detailing asbestos fiber counts and structural identification for air samples from a NYC education facility.
6 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293526
TEM asbestos analysis parameters for NSHS site, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270812
TEM asbestos analysis, New Stuyvesant High School exterior/interior, received 10/24/01.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293448
TEM analysis data for NSHS; exterior/interior openings documented.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270878
Final TEM analysis report; sample 19 for New Stuyvesant HS.
6 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000292759
TEM asbestos analysis with SAED and EDS parameters for New Stuyvesant High School, received 10/28/01.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293948
TEM asbestos fiber analysis for New Stuyvesant High School exterior/interior, received 10/25/01.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293972
TEM analysis; exterior/interior; received 10/26/01.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270723
TEM analysis with SAED/EDS for New Stuyvesant High School, received 10/22/01.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270195
TEM analysis of air samples at Stuyvesant High School; includes volume and opening.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293944
TEM analysis of air samples at New Stuyvesant HS, exterior/interior, Oct 2001.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM asbestos analysis with SAED and EDS parameters for New Stuyvesant High School, received 10/28/01.
Similar indexed content
TEM asbestos fiber analysis for New Stuyvesant High School exterior/interior, received 10/25/01.
Similar indexed content
TEM analysis; exterior/interior; received 10/26/01.
Similar indexed content
TEM analysis with SAED/EDS for New Stuyvesant High School, received 10/22/01.
Similar indexed content
NYC-WTC_000270195
TEM analysis of air samples at Stuyvesant High School; includes volume and opening.
Similar indexed content