ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10875 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/24/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No. 5 74 8 6206B Exterior Interior o£ Building Sl Roof Date Received: 10/23/^ Grid Openings Analyzed;__ 4

Project Sample No.:_14 Average Grid Opening: 1C6.Q0 um

Air Volume: 1928 liters Total Area Analyzed: C.0450 mTn2

Filter Type: MCE 25 mm diam. Pore Size: 0.45 um Analytical Sensitivity:22^2 s/mm2 Effective Area: 385 mm2 0.0044 s/cc

FIBROUS PARTICULATES TkNALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc ngm/m3•

Chrysotile Asbestos 0 c 0 0 0 0 0. 0 0.0000 0

Amphibole Asbestos 0 c 0 0 0 0 0. 0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Nor.-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A Tne estimated uncertainty of this analysis is 1 standard deviation,

Non-asbestos fiber i.d. (EDS/SAED) .- None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003082560

NYC-WTC_000293862

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000293862Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270675

TEM-based asbestos fiber analysis for New Stuyvesant H.S., Oct 2001.

Similar indexed content

NYC-WTC_000292747

Asbestos TEM analysis for exterior/interior of New Stuyvesant H.S., Oct 28–29, 2001.

Similar indexed content

NYC-WTC_000270980

TEM asbestos analysis for exterior/interior of New Stuyvesant High School, received 10/28/01.

Similar indexed content

NYC-WTC_000293975

Asbestos fiber analysis by TEM/SAED/EDS for New Stuyvesant High School exterior and interior samples, received Oct 26, 2001.

Similar indexed content

Compare copies and versions →