NYC-WTC_000270379
TEM asbestos analysis report for exterior/interior of building, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Asbestos TEM analysis parameters for New Stuyvesant HS exterior/interior; Oct 2001.
NYC-WTC_000293860OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/24/01
ASBESTOS FIBER TkNALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763*, Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: New Stuwesant H.S., 34 5 Chambers St,, NY, NY TEM Sample No.: 574S 62066 Exterior & Interior of Building & Roof Date Received: 10/23/01 Grid Openings Analyzed:__ 4
Project Sample No.:_12 Average Grid Opening:1^06;0.0 i^
Air Volume : 1928]J^t^r^ Total Area Analyzed: 0.0450 mm2
Filter Type: MCE 25 mm diam., Pore Size: 0.45 urn Analytica1 Sensitivicy: 22.2 s/mm2 Effective Area : 385 nim2 0.0044 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. struct. Filter Air Fibers Bundles Clusters Struct. Struct >=5uTn Struct/mniG Struct/cc nqm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0. 0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation,
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by; Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC100_003082558
NYC-WTC_000293860
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000270379
TEM asbestos analysis report for exterior/interior of building, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270356
TEM analysis and SAED/EDS, NSHS sample NSHS-EIR-10/11-06, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270273
Asbestos TEM analysis with SAED/EDS for Stuyvesant HS, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293857
Asbestos TEM analysis parameters for New Stuyvesant HS exterior/interior; Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293689
TEM asbestos analysis of New Stuyvesant H.S. samples, including SAED/EDS data.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270978
TEM asbestos analysis for New Stuyvesant High School site, received 10/28/01.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270678
TEM analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270439
AHERA TEM analysis and SAED/EDS identification for New Stuyvesant High School, received 10/15/01.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293944
TEM analysis of air samples at New Stuyvesant HS, exterior/interior, Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270968
TEM asbestos analysis with SAED/EDS for New Stuyvesant HS exterior/interior, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182597
Technical data sheet recording air volume and microscopic analysis parameters for exterior and interior samples at Stuyvesant High School.
5 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270880
TEM analysis; exterior/interior, sample 13.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000270379
TEM asbestos analysis report for exterior/interior of building, Oct 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270356
TEM analysis and SAED/EDS, NSHS sample NSHS-EIR-10/11-06, Oct 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270273
Asbestos TEM analysis with SAED/EDS for Stuyvesant HS, Oct 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293857
Asbestos TEM analysis parameters for New Stuyvesant HS exterior/interior; Oct 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293689
TEM asbestos analysis of New Stuyvesant H.S. samples, including SAED/EDS data.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270978
TEM asbestos analysis for New Stuyvesant High School site, received 10/28/01.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM asbestos analysis report for exterior/interior of building, Oct 2001.
Similar indexed content
NYC-WTC_000270356
TEM analysis and SAED/EDS, NSHS sample NSHS-EIR-10/11-06, Oct 2001.
Similar indexed content
NYC-WTC_000270273
Asbestos TEM analysis with SAED/EDS for Stuyvesant HS, Oct 2001.
Similar indexed content
Asbestos TEM analysis parameters for New Stuyvesant HS exterior/interior; Oct 2001.
Similar indexed content
TEM asbestos analysis of New Stuyvesant H.S. samples, including SAED/EDS data.
Similar indexed content