TEM analysis, Lab Sample 61949, 10/22/01

Machine-extracted title · confidence 40%

TEM analysis for Lab Sample 61949; 25 mm, 80 kV; EDS data.

NYC-WTC_000293835
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC ASSOCIATES INC. TEM ANALYSIS LAB GROUP #: 5739 - 10/22/01

Lab Sample No. 61949 Type MCE 2 5 mrn Ooeracor

Client Spl- No. L4 Filter Area 385 mm'

Instrumenc I.D. SM.IO CRX Grxd I.D. Disk No.

Screen Magnification 16,40QX (GO Area 0 . 01124 mTn'^2 Comments Acc. Voltage 80 kV No. GO to be Anaiyted ( 3.147 Struct. CcrsDd 7 0 s/mm'*'2 . )

GO. structure structure Type Length I.D. of Structure EDS (Nonasb. No. Coord. No. F B C M >0.5 um Sum Chrys. Amphibole Nonasb. Ambig./ND Elements) < 5 um

67^ r 4 X A 1 (L

Photo No. (from I in 5 asbestos— Identify all structures using EDS Check diffraction for asbeatos Store all unrepeated spectra— containing samples) Grid acceptance:! structures up to TOs/i^in (let 4) <S0X undiaaolvec filter, overlapped or folded Struct. = > O.Sum it > 5:1 Aspect Ratio <10X particulate coverage >50% coverage Ns Not Observed (EDS spectrum or dlffracLlon pattern) at least 20 unfolded or overlapped grid squares Tetals Positive diffraction pattern properties conforming <5X holes or opaque areas F B C M > Sum to laboratory identification criteria observed. -Unused portion of filter Per ehryaoUls: Q.73nm saaalne for (020) refleclioat, 0.53nm spscing for the layer line repeat, streaking Chrysotile -Avoided portion or (LIO) and (130) reflections. of fitter Par amphibolea: O.SOnm layer Une repeat, ant) approx. Portion of filter (Zmm wide) 3.S ratio of non-twinned layer Une spot spacing to subject to examination Amphibole layer line repeat distance (Q.53nm).

EDS spectrum conforming to laboratory Identification criteria observed. AMPHIBOLES Ambiguous F= Single Fiber (1-3 Intersections = 1-3 fibers) Amosite B= Bundle (>3 fibers Cl fiber diameter apart) Z5mm niter Crocidolite Non-asbestos C= Cluster (>3 intersections) J Stopping Rules: I----------- - M= Uetrlx Anthophyllite NSD= No Structures Detected [ >50 s/G.O. or in let 4 G.O. Tremolite Actinolite Non-Identified L\nATA\PRIVATE\MIKiC\CADDV£M3 9/22/08

CITY_21MC100_003082534

NYC-WTC_000293835

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000293835Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

TEM analysis, 62428, 10/28/01

NYC-WTC_000292777

TEM analysis for Lab Sample 62428; MCE 25 mm; EDS data; New Stuyvesant High School project.

Similar indexed content

Compare copies and versions →