ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10875
28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187
Long Island City, NY 11101 Report Date: 10/23/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method; AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: Nev Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5739 - 61938
Exterior & Interior cf Building Roof
Date Received: 10/22/01 Grid Openings Analyzed:__ 4
Project Sample No. Average Grid Opening :
Air Volume ;^ 1936 }Ate^ Total Area Analyzed: 0.0450 mm2
Filter Type: MCE 25 mm diam., Pore Size: 0.45 urn Analytical Sensitivity
Effective Area: 385 mm2 0.0044 s/cc
FIBROUS PARTICULATES T^ALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct >=5um Struct/miT,2 Struct/cc nqm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 C 0 0 0 0 0. 0 0.0000 0
Total asbestos [includes ambiguous structures) 0 0 0.0 0.0000 0
Nor.-Asbestos 0 c 0 0 0 0 0.0. 0.0000 N7A
No Identification 0 0 0 0 0 0 0.0 0.0000 N7A
Totals (All Structures) 0 0 0.0 0.0000 N7A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Roman Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
CITY_21MC100_003082502
NYC-WTC_000293807