NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM analysis, New Stuy HS, Oct 2001

Machine-extracted title · confidence 38%

TEM asbestos analysis of New Stuyvesant H.S. samples, including SAED/EDS data.

NYC-WTC_000293689
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1167 Long Island City, NY 11101 Report Date; 10/20/01

ASBESTOS FIBER TkNALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 7631, Vol. 52, No. 210, October 30, 1987

Sample Ident-ification Analysis Parameters

Project/Site: New StuyA^esan- H.S., 345 Chambers St., NY, NY TEM Sample No.: 5730 - 61706 Various Sites Inside and Outside the Building Date Received:l^/l^/01 Grid Openings Analyzed:__ 4

Project Sample No. Average Grid Opening: 106.00 um

Air Volume : 1928 1ite^ Total Area Analyzed :0;^04^0 rrim2

Filter Type: ' MCE 25 mm diam., Pore Size: 0.45 urn Analytical Sensitivity -. 22.2 s/mm2 Effective Area: 385 mm2 0.0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mrri2 Struct/'cc nqm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 G 0 0 0 0.0 0.0000 No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type; None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by; Report Reviewed by;

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003082370

NYC-WTC_000293689

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000293689Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293860

Asbestos TEM analysis parameters for New Stuyvesant HS exterior/interior; Oct 2001.

Similar indexed content

NYC-WTC_000270379

TEM asbestos analysis report for exterior/interior of building, Oct 2001.

Similar indexed content

NYC-WTC_000293857

Asbestos TEM analysis parameters for New Stuyvesant HS exterior/interior; Oct 2001.

Similar indexed content

Compare copies and versions →