ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/18/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHE’RA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification ^ia3A£SisParamet^rs

Project/Site: New stuyvesant H.S., 345 Chambers St., NY, NY TEM sample No,: 5725 61646 Exterior & Interior of Building & Roof Date Received: 10/18/01 Grid Openings Analyzed:__4

Project Sample Average Grid Opening: 106.00 um

Air Volume Total Area Analyzed: 0.0450 mm2

Filter Type: MCE 25 mm diam. Pore Size: 0.45 um Analytical Sensitivity: 22.2 s/mniz Effective Area: 385 mm2 0,0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct, Filter Air Fibers Bundles Clusters Struct Struct > = 5um Struct/mm? Struct/cc nqm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0 . 0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0 . 0000 0 Kon-Asbestos 0 0 0 0 0 0 0.0 0.3000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0 . 3000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by; Report Reviewed by:

Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003082321

NYC-WTC_000293646

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000293646Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293896

TEM with SAED/EDS identification; exterior/interior of building.

Similar indexed content

NYC-WTC_000270551

TEM asbestos analysis for exterior & interior of New Stuyvesant H.S.; includes sample numbers and date.

Similar indexed content

NYC-WTC_000270665

TEM analysis by SAED/EDS for New Stuyvesant HS, exterior/interior, 10/2001.

Similar indexed content

NYC-WTC_000293638

TEM asbestos analysis with SAED/EDS for New Stuyvesant High School, Oct 2001.

Similar indexed content

Compare copies and versions →