Asbestos TEM analysis, New Stuyvesant HS, Oct 2001

Machine-extracted title · confidence 42%

TEM asbestos analysis; exterior/interior of New Stuyvesant High School, Oct 2001.

NYC-WTC_000293639
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/18/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED.i and Energy-Dispersive X-RAY Spectroscopy (EDS) Method; AHERA Final Rule, EPA Federal Register (40 CFR, Fart 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Site: New Stuyvesant H.S., 34b .Chambers St., NY, NY TEM Sample No.; 5725 61636 Exterior & Interior of Building & Rocf Date Received: 10/18/01 Grid Openings Analyzed:__ 4

Project Sample No. Average Grid Opening; 106.00 urn

Air Volume;19281iters Total Area Analyzed :0 j045 0 rnni2

Filter Type: MCE 25 mm diam., Pox-e Size; 0.45 urn Analytical Sensitivity :J2-;.2 s2trirn2 Effective Area: 385 rnm2 C■0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5uin Struct/mrn2 Struct/cc ngm/mS

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.ODOC 0

Amphibole Asbestos 0 C 0 C 0 0 0,0 0.0000 0

Ambiguous 0 0 0 c 0 0 0.0 0.0000 c

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 C 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED); None detected Amphibole Asbestos Type; None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by. Report Reviewed by;

Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003082311

NYC-WTC_000293639

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000293639Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293696

TEM asbestos analysis of New Stuyvesant H.S. samples, including SAED/EDS results.

Similar indexed content

NYC-WTC_000293904

TEM analysis parameters; exterior/interior, 1944 liters air volume.

Similar indexed content

NYC-WTC_000293726

TEM analysis of New Stuyvesant HS samples; includes air volume and opening data.

Similar indexed content

NYC-WTC_000293978

TEM analysis on exterior/interior building samples; TEM sample 5775, received 10/26/01, analyzed date similar.

Similar indexed content

Compare copies and versions →