ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/18/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction fSAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 3C, 1987

Sample Identification Analysis Parameters

Proj ect/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5716 61538 Exterior & Interior of Building & Roof Date Received; 10/17/01 Grid Openings /Analyzed;__ 4

Project Sample Mo. : NSHS-SIR-10/17 - 6 Average Grid Opening: 106.00 um

Air Volume :J,82912.t€rs Total Area Analyzed; 0^0450mt^

Filter Type; MCE 25 mm diam. , Pore Size: 0.45 um Analytical Sensitivity :22;.^2 sAnm2 Effective Area: 385 Trim2 0.0045 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct, struct > = 5um Struct/mm2 Struct/cc ngm/m3

C'nrysotile Asbestos 0 0 u 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0. 0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) c 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by;

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003082288

NYC-WTC_000293622

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000293622Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293816

TEM analysis with SAED/EDS, New Stuyvesant H.S., Oct 2001.

Similar indexed content

NYC-WTC_000294013

TEM analysis of exterior/interior air at New Stuyvesant H.S., Oct 2001.

Similar indexed content

NYC-WTC_000270413

TEM asbestos analysis with SAED/EDS for New Stuyvesant HS, Oct 2001.

Similar indexed content

Compare copies and versions →