ATC ASSOCIATES INC. TEM ANALYSIS LAB GROUP #: 5598 - 10/04/01
Lab Sample No. 59931 Filter Type MCE 25 mnt Operator Client SDl. No. 05 Filter Area 385 mm"2 Instx'ument I.D. EM 10 CRX Grid I.D. Disk No. Screen Magnification 16,400X (GO) Area Q.01124 mm"2 Comments Acc. Voltage 8 0 kV No. GO to be Analysed ( 3.147 Struct. Corspd. to 70 s/'nm'^2.)
GO. Structure Structure Type Length I.D. of Structure EDS >0.5 um (Nonasb. No. Coord. No. F B C M Sum Chrys. Amphibole Nonasb. Ambig./ND Elements) < 5 um
Photo No. (from 1 in 5 as!»estoB— identify all structures using EDS Check diffraction for asbestos Store all unrepeated spectra— containing samples) Grid acceptance:! structures up to TOa/^n (l»t 4) <S0X undissoivetT filter, overiappeci or folded Struct. = > O.Sum > 5:1 Aspect Ratio <IOX particulate coverafe >50X coverage Ns Not Observed (EDS spectrum or diffraction pattern) at least 20 unfolded or overlapped grid squares Totals <8X holes or opaque areas F B C M > Sum Positive diffraction pattern properties conforming to laboratory identification criteria observed. -Unused portion For ehryeoUle: Q.73nm SMcinc for (020) r«neeUena, of niUr Chrysotile O.&Snra spacing for the laver line repeat, streaking -Avoided portion of (110) and (lao) renecUons. of niter For amptalbolea: O.Mnm layer line repeat, and approx. (8mm Vido] 3.S ratio of non-tvinned layer line spot spacing la Amphibole layer Une repeat distance (Q.93nm). v/= EDS spectrum conforming to laboratory Ambiguous identifieation criteria observed. AMPHIBOLES P= Single Fiber (1-3 intersections - 1-3 fibers) _ Amosite B= Bundle (>3 fibers <1 fiber diameter apart) 2Smm filler Crocidolite Non-asbestos S= SCte _____ suppln, Hui..: I______ Anthophyllite NSD= No Struelurn DeUcUd | >5° »/C.O. or In l.t 4 C.O. | Tremolite Actinolite Non-Identified U\D*TA\PBtVATE\»llKEC\CAOD\reiia 0/22/08
CITY_21MC100_003081999
NYC-WTC_000293362
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000270567
TEM analysis parameters and EDS details for asbestos structure identification.
7 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293360
TEM analysis lab data sheet with structure/EDS data; 10/04/01.
8 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270559
TEM analysis parameters and EDS details for asbestos structure identification.
8 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293876
TEM analysis of sample 52052; EDS data and structure IDs; notes on analysis parameters.
8 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270950
TEM analysis record with sample coordinates and structure IDs for asbestos evaluation.
8 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000271004
TEM analysis data set for asbestos structure characterization at 5790 LAE group, Oct 29, 2001.
8 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237515
Laboratory report documenting transmission electron microscopy analysis of sample 62005 for asbestos identification.
8 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237516
Laboratory report documenting transmission electron microscopy analysis of sample 62006 for asbestos identification.
8 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237494
Laboratory report documenting transmission electron microscopy analysis of a bulk sample collected on October 23, 2001.
7 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000174909
Laboratory report containing transmission electron microscopy data and images for asbestos fiber identification from samples analyzed in October 2001.
8 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237528
Laboratory report from ATC Associates documenting transmission electron microscopy analysis of a sample collected on October 23, 2001.
8 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237291
Raw data sheet from transmission electron microscopy analysis of air samples collected at 40 Rector Street on September 28, 2001.
8 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000237515
Laboratory report documenting transmission electron microscopy analysis of sample 62005 for asbestos identification.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237516
Laboratory report documenting transmission electron microscopy analysis of sample 62006 for asbestos identification.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270567
TEM analysis parameters and EDS details for asbestos structure identification.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237494
Laboratory report documenting transmission electron microscopy analysis of a bulk sample collected on October 23, 2001.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293360
TEM analysis lab data sheet with structure/EDS data; 10/04/01.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270559
TEM analysis parameters and EDS details for asbestos structure identification.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000237515
Laboratory report documenting transmission electron microscopy analysis of sample 62005 for asbestos identification.
Similar indexed content
NYC-WTC_000237516
Laboratory report documenting transmission electron microscopy analysis of sample 62006 for asbestos identification.
Similar indexed content
NYC-WTC_000270567
TEM analysis parameters and EDS details for asbestos structure identification.
Similar indexed content
NYC-WTC_000237494
Laboratory report documenting transmission electron microscopy analysis of a bulk sample collected on October 23, 2001.
Similar indexed content
NYC-WTC_000293360
TEM analysis lab data sheet with structure/EDS data; 10/04/01.
Similar indexed content