PCB wipe sample report, HS for Leadership & [name] HS

Machine-extracted title · confidence 46%

PCB wipe sample report for High School for Leadership and the associated location, May–June 2002.

NYC-WTC_000291462–000291463
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

600 West Cummings Park, Suite 6500 1A1 Woburn, Massachusetts 01801-6350 wwwatc-erviro com 781.932,9400 Fax 781.932,6211 ASSOCIATES INC.

June 28, 2002

Mr. Bernard P. Orlan Director, Environmental Health & Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101 -4008

Re: Wipe Samples for Polychlorinated Biphenyls High School for Leadership & Public Service 90 Trinity Place New York, New York ATC Project No. 15-19125-0290

Dear Mr. Orlan:

ATC Associates Inc. (ATC) is pleased to provide this report of the results of the wipe samples for polychlorinated biphenyls (PCBs) collected on May 10 & 17, 2002, at the referenced location. The New York City Board of Education (BOE) requested these samples to evaluate possible contamination in the school building.

Scope of Work

The samples were collected using sterile gauze pads and hexane as a solvent. The solvent was provided and samples were analyzed by PSC Analytical Services, Inc. (PSC), an American Industrial Hygiene Association-accredited laboratory in Reading, PA. The PCB analysis was performed using EPA Method 8082B.

Tenzin Namgyal, Industrial Hygienist of ATC’s New York City office, collected the samples consistent with generally accepted industrial hygiene practices. The results of the sampling represent conditions found on the date the samples were collected.

The areas sampled were: Main Lobby - Floor, Sth Floor by Elevator - Floor and 10th Floor by the Elevator - Floor.

Results

On each day, ATC submitted three samples for PCBs to PSC for analysis. A copy of the laboratory report is provided in the Attachment. The area for each wipe sample was 100 square centimeters (lOOcnV). ‘

CITY_21MC100_003078947

NYC-WTC_000291462

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000291462Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000399151

ATC report of PCB wipe samples collected 6/2002 at NYC school location.

Similar indexed content

NYC-WTC_000399146

ATC report for PCB wipe samples at High School for Leadership & [name], NYC, May–June 2002.

Similar indexed content

Compare copies and versions →