NYC-WTC_000290089
Lab report analyzing aggregate and materials for World Trade Center project, with strength testing details.
4 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗Shop drawing review for World Trade Center construction; reference to testing lab.
NYC-WTC_000290081–000290084OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
SHOP DRAWING REVIEW WORK WAY PnoegEP 2N WORK aWY PROCCEO SIIWECT TO THE O-IANGeS PIDICAtTP. RESVOttnTALNCTREQWRSD. 2R WORK ftJAY Wf > WXKD OIJ RESUB^rTTAt K£GUWED. WORK KAY PRCCEEtJ CW OrHEM PARTS ~ ■ WORaT^Y idOT PROCEED. REV^S AhO' RfciUSWT.’
4 Corrections or to siifcmtKdU <Juring this rolvow do not ra'iovs conlTJcnor from CERTIFIED TESTING LABORATORIES, INC. compliance with tlve roquJromontc of ttw dmwinga and
general conformance with tho daclgn concept of the project and genonil contpiUmco with the infonrsUon DATE: May 9, 2002 given tn the contract docuntoTrta. The contactor la responsible for conflnm.iQ conoictlna oU LAB#: 12737 quantItJas and dirnencbns; sckcdr.g fabrication processes and techniqucc of construction; coordlrutlng hlQ worti wUh that of oUior trados and CLIENT: Civetta Cousins JV performing hia worti In a safe and satisfactory tnannor. Thia review doos not indicate or imply any approval of 1100 East 156'^ Street Change* in time or changos In coat Bronx, NY 10474 MUESER RUTLEDGE CONSULTING ENGINEERS, INC. PROJECT: World Trade Center, New York Cast in place wall G40 to G44 Mt)e jy 4 STRENGTH REQUIRED: 5000 psi plus 25% @ 28 days (regular)
SUBJECT: Analysis of Aggregate and Concrete Mix Design
FOR: Prequalified Trial Mix Design in accordance with NYC Code 27-605
SUPPLIER: Empire Concrete The following materials were submitted by Empire Concrete as typical of those proposed to be furnished for this project.
Cement: Norval 236-59-SM Type 1 ASTMC 150 Fine Aggregate: Long Island Natural ASTM C 33 Coarse Aggregate: New York Traprock ASTM C 33 Admixture #1: WR Grace Daravair, Cal #679-53-SM ASTM C 260 Admixture #2: WRDA Hycol ASTM C 494
COARSE AGGREGATE Gradation Test Sieve Size Percent Passing ASTM C 33 # 67 1” 100.0 100 3/4” 92.4 90-100 /a” 63.7 3/8” 25.9 20-55 #4 4.8 0-10 #8 2.1 0-5 Unit Weight, Dry Rodded ,99.8 pounds Specific Gravity.............. .2.80
2623 Roberts Avenue • Bronx. New York 10461 • [718] 824-1616 • Fax (718) 792-Q982
CITY_21MC100_004713850
NYC-WTC_000290081
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000290089
Lab report analyzing aggregate and materials for World Trade Center project, with strength testing details.
4 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000290085
Material strength analysis for concrete aggregates and admixtures for World Trade Center.
4 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000389414
Laboratory report on aggregate and cement materials for World Trade Center wall G40-G44.
3 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000279968
Strength test analysis for aggregates and design materials for wall G40–G44 cast-in-place.
4 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188034
Laboratory report analyzing aggregate and concrete mix designs for World Trade Center construction.
3 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000279972
Analysis of aggregate and design materials for cast-in-place wall G40–G44 per NYC code.
3 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000407889
Client lab report with test data and confidential protective-order note.
3 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000388719
Laboratory results for concrete pour at Civetta-Cousins JV, May 9, 2002.
2 shared non-person entities · 1 shared topics · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000290047
Lab results for 7-day and 28-day compressive strength tests; cylinders prepared.
2 shared non-person entities · 1 shared topics · similarity 0.929
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000290048
Colorimetric and physical test results for specified aggregate samples.
2 shared non-person entities · similarity 0.925
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000407888
Lab results for fine aggregate; passing percentages and test data.
2 shared non-person entities · similarity 0.911
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199901
Laboratory report detailing concrete mix design specifications for a New York City Department of Transportation project in Queens.
Similar document embedding; no shared entity or topic indexed. · similarity 0.906
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000389414
Laboratory report on aggregate and cement materials for World Trade Center wall G40-G44.
Similarity score 0.973 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000290089
Lab report analyzing aggregate and materials for World Trade Center project, with strength testing details.
Similarity score 0.968 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000290085
Material strength analysis for concrete aggregates and admixtures for World Trade Center.
Similarity score 0.968 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000279972
Analysis of aggregate and design materials for cast-in-place wall G40–G44 per NYC code.
Similarity score 0.966 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000279968
Strength test analysis for aggregates and design materials for wall G40–G44 cast-in-place.
Similarity score 0.966 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188034
Laboratory report analyzing aggregate and concrete mix designs for World Trade Center construction.
Similarity score 0.963 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000290089
Lab report analyzing aggregate and materials for World Trade Center project, with strength testing details.
Similar indexed content
NYC-WTC_000290085
Material strength analysis for concrete aggregates and admixtures for World Trade Center.
Similar indexed content
NYC-WTC_000389414
Laboratory report on aggregate and cement materials for World Trade Center wall G40-G44.
Similar indexed content
NYC-WTC_000279968
Strength test analysis for aggregates and design materials for wall G40–G44 cast-in-place.
Similar indexed content
NYC-WTC_000188034
Laboratory report analyzing aggregate and concrete mix designs for World Trade Center construction.
Similar indexed content