NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

OSHA sampling results summary, WTC site, Feb 2002

Machine-extracted title · confidence 52%

Overview of asbestos and noise sampling at WTC rubble area; results indicate concentrations mostly below OSHA limits.

NYC-WTC_000289982–000289984
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

power tools during demolition activities at 7 WTC's parking garage. Most of the work areas where apparent overexposures to silica occurred were in the rubble pile/pit: an area

where OSHA continues to encourage the use of respiratory protection

Organic

Compounds: OSHA has taken a total of 636 samples (excluding bulk and blank samples) for organic compounds such as acetaldehyde, acrolein, acrylonitrile, benzene, 2-hutanone

carbofurans, dioxin. PCBs, ethyl benzene, formaldehyde. Freon R-22

(chlorodiflouromethane), hexone, isocyanates ( e g MDf TDI). perchioroethylene polynuclear aromatics, phosgene, styrene, toluene, I I- butadiene, tncnloroethylene. vinyl chloride, glutaraldehyde, and xylene. Screening .samples initially showed elevated levels

of some organic chemicals resulting from ihe fires burning in the rubble pile. .Subsequent

personal and area samples show worker exposure levels to be below OSHA limits. However, one personal sample result for a benzene sample taken was found to be at the S

hr. OSHA Allowable Limit concentration of 1 ppm fhis was found on a backhoe operator moving debns on 1 0/7/01 See information below for the specific counts in

regards lo polyiiucleai aroiiialics. Freon R-22, phosgene and dio.vn

Dioxins: OSHA has taken 10 dioxin samples (excluding blanks) in the plume over hot spots in (and around the perimeter of) the rubble pile. Dioxin levels detected around the perimeter art

lower than those found directly over the pile. To date, only one sample taken on the rubble pile showed dioxin levels which exceeded background levels Dioxins art-

considered collectively as suspect human carcinogens OSHA docs not have a PEL for

dioxins-

Polynuclear Aromatic

Hydrocarbons OSHA has taken 11d samples (excluding blanks! the majority of the samples have not

shown the presence of bcnzo(a)pyTene and/or one or more of five additional fused polycyclic hydrocarbons: anthracene, acridine, pyrene, chrysene and phenanthrene.

Sample results to date have identified eight samples which reached or exceeded OSHA t coal tar pitch volatile PEL of 0.2mg/m These personal samples were taken on the pile

on iron workers and grappler operators, OSHA contmue.s to strongly recommend the

use of respiratory protection when workni.g on the rubble pile.

Freon R-22,

Hydrogen Fluoride & Phosgene: OSH.A has taken a total of 202 samples for Freon R-22 (chlorodiflouromethane),

hydrogen fluoride, and phosgene. Only one Freon sample resulted in a detectable level o( 6.4 ppm during the transfer of Freon from the auxiliary chiller, and all other .samples were

none-detected. OSH.A doe,s not have an exposure limit for Freon R -22. iThe NIOSH

Page 2 of 2

CITY_21MC100_008912976

NYC-WTC_000289983

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000289983Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →