power tools during demolition activities at 7 WTC’s parking garage. Most of the work
areas where apparent overexposures to silica occurred were in the rubble pile/pit; an area
where OSHA continues to encourage the use of respiratory protection.
Organic
Compounds: OSHA has taken a total of 625 samples (excluding bulk and blank samples) for organic
compounds such as acetaldehyde, acrolein, acrylonitrile, benzene, 2-butanone,
carbofurans, dioxin, PCBs, ethyl benzene, formaldehyde. Freon R-22
(chlorodiflouromethane), hexone, isocyanates (e.g. MDI, TDl), perchloroethylene,
polynuclear aromatics, phosgene, styrene, toluene, 1-3 butadiene, trichloroethylene, vinyl
chloride, glutaraldehyde, and xylene. Screening samples initially showed elevated levels
of some organic chemicals resulting from the fires burning in the rubble pile. Subsequent
personal and area samples show worker exposure levels to be below OSHA limits.
However, one personal sample result for a benzene sample taken was found to be at the 8-
hr. OSHA Allowable Limit concentration of 1 ppm. This was found on a backhoe
operator moving debris on 10/7/01. See information below for the specific counts in
regards to polynuclear aromatics. Freon R-22, phosgene and dioxin.
Dioxins: OSHA has taken 10 dioxin samples (excluding blanks) in the plume over hot spots in (and
around the perimeter of) the rubble pile. Dioxin levels detected around the perimeter are
lower than those found directly over the pile. To date, only one sample taken on the
rubble pile showed dioxin levels which exceeded background levels. Dioxins are
considered collectively as suspect human carcinogens. OSHA does not have a PEL for
dioxins.
Polynuclear Aromatic
Hydrocarbons OSHA has taken 110 samples (excluding blanks). The majority of the samples have not
shown the presence of benzo(a)pyrene and/or one or more of five additional fused
polycyclic hydrocarbons: anthracene, acridine, pyrene, chrysene and phenanthrene.
Sample results to date have identified eight samples which reached or exceeded OSHA’s
coal tar pitch volatile PEL of 0.2mg/m’. These personal samples were taken on the pile
on iron workers and grappler operators. OSHA continues to strongly recommend the
use of respiratory protection when working on the rubble pile.
Freon R-22,
Hydrogen Fluoride
& Phosgene: OSHA has taken a total of 202 samples for Freon R-22 (chlorodi flouromethane),
hydrogen fluoride, and phosgene. Only one Freon sample resulted in a detectable level of
6.4 ppm during the transfer of Freon from the auxiliary chiller, and all other samples were
none-detected. OSHA does not have an exposure limit for Freon R-22. (The NIOSH
Page 2 of 3