NYC 9/11 Public Portal Document

09/26/2001 10:31 7183900915 SAFETY ENVIRONMENTAL PAGE 06

SAFETY ENVIRONMENTAL (718) 390-0914 CO. OF N.Y. INC. Fax (718) 390-0915

33 Clinton Avenue Staten Island, NY 10301 CLIKNT: NYC D.O.T. SITE: 2 RECTOR STREET, NEW YORE, NY RE: ASBESTOS AIR MONITORING ANO TESTING 6” FLOOR OPPlCK SPACES DATE SAMPLE COLLECTED; 9/25/01 DATS SAMPLE ANALYZED: S/26/01 PILE NO.; 01-X37 BATCH #; 9-017 SAMPLE TYPE: AIK QUALITY CERTIFICATE OP ANALYSIS Airborne asbestos analysis by NIOSH method no. 7400-pha3e contrast microscopy New York State ELAP * 11475, American Industrial Hygiene association # 17049. Microscope Type-PCM, Make-Olympus, Model CH-2 SAMPLZ SAMPLE LOCATION TOTAL PLOW VOLUME RESULTS NUMBER TIME RATE (L) PIBERS/ SAMPLED [L/Min) CC (MIN) AQl ' CENTER OF GHIn’oFFICE 120 10 1200 0.002 AQ2 CENTER DEP DIRECTOR OFF 120 10 1200 0.003 AQ3 CENTER FABRE-J OFFICE 120 10 1200 0.002 AQ4 FRIDMAN CUBICLE 120 10 1200 0.002 AQ5 MAKARIOUS OFFICE 120 10 1200 0.002 AQ6 CORRIDOR NR EX D ENTRANCE 120 10 1200 0.003 AQ7 RM 6NW BLUE PRINTS FILE 120 10 1200 0.003 AQ8 SHAH i BERENS OFFICE 120 10 1200 0,005 AQ9 ELEVATOR BANK 120 10 1200 0.004 AQIO KESTELBOYM OFFICE 120 10 1200 0.004 AQll CORRIDOR SW END 120 10 1200 0.004 AQl 2 CORRIDOR CENTER OF S SIDE 120 10 1200 0.003 AQl 3 CENTER OF RM 3 WEST 120 10 1200 0.003 AQl 4 COPIER ROOM 120 10 i 1200 0.004

Environmental Engineering Consultant • Asbestos, Lead, and Gas Air Monitoring & Testing, Inspections Project Management “ Laboratory Analytical Testing Services • Abaternent Design • Phase 1 & 2

CITY_21MC100_006672334

NYC-WTC_000289970

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000289970Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →