HEALTH & SAFETY SERVICES, IRC. PO Box 249 • Hammonton/MJ 08037 • (609) 704-8850 • Fax (609) 561-7646

Indoor Air Quality • Asbestos & Lead I^anagement • Site Assessments

January 6, 2002

Mr. Wayne Barthel Fleet Manager GSA Fleet Management 2890 Woodbridge Avenue Building 201 ■ aw Edison, New Jersey 08837 i Re: Automobile Asbestos Contamination Investigation Vehicle Tag# 18013

Dear Mr, Barthel:

Per your request, Health & Safety Services, Inc. provided the services of an EPA/AHERA Licensed Asbestos Building Inspector to determine the extent of contamination of a cai' that has been subject to suspect asbestos containing debris.

Two types of samples were collected from the automobile:

A bulk sample was collected from under the hood of the car adjacent to the cowl. The sample was collected using 40 CFR 763 protocols and were analyzed utilizing Polarized Light Microscopy techniques by NVLAP approved laboratories. Upon analysis of the sample, asbestos was detected above the regulatory limit of 1% by weight.

A Transmission Electron Microscopy Micro vacuum Dust sample was collected from the back seat of the car. The sample was collected using a 25-mm diameter MCE filter contained in a three- piece standard TEM AHERA air cassette with a one inch piece of tubing attached to the face cap as a nozzle. The end of the nozzle is cut at a 45" angle. The cassette is connected to a personal sampling pump with flexible tubing and calibrated at 2 liters per minute. The area to be sampled is then vacuumed for 2 minutes, or until there is no visible dust remaining in the sampling area. At the end of sampling, the cassette is turned upward before shutting off the power to the pump. The no2zle is plugged and the cassette end sealed with an end plug. The assembly is appropriately packaged to prevent separation of the nozzle from the cassette and sealed in a plastic bag. The sample was analyzed for the presence of asbestos with the use of a Transmission Electron Microscope. Asbestos was detected and the type i.s consistent wth the material found under the hood of the car.

C;S.\ IHeel Management Vehicle #18013

CITY_21MC100_008906201

NYC-WTC_000289915

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000289915Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →