NYC-WTC_000289613
Narrative on health concerns and rationale for sampling dust and air post-9/11.
5 shared non-person entities · 1 shared topics · similarity 0.916
machine-extracted · confidence unavailable · Check page ↗Table of fiber types with TLV values for MMVFs, glass fibers, and related materials.
NYC-WTC_000289637–000289652OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
FEB-22-02 11=44 FROM:ATSDR DHAC OD ID:4044980073 PAGE lB/19
potential human toxicity. Based on this view, the 7. Zussman, J,: The Mineralogy of Asbestos. In: TLV-TWA for RCF is set at a lower level than for the Asbestos: Properties, Applications and Hazards. L. other SVPs, namely, 0.2 f/cc, with an A2, Suspected Michaels and S.S. Chissick, Eds. John Wiley & Sons, New York (1979). Human Carcinogen, notation. Although the available 8. Antonsson, A.; Runmark, S.: Airborne Fibrous Glass data are incomplete, 0.2 f/cc is considered at this and Dust Originating from Worked Reinforced time to be a cautious number that should be Plastics. Am. Ind. Hyg. Assoc. J. 48:684-687 (1987). sufficiently protective for malignant and 9. Ganter, BA.: Respiratory Hazard from Removal of nonmalignant health effects among exposed Ceramic Fiber Insulation from High-Temperature individuals. Industrial Furnaces. Am. Ind. Hyg. Assoc. J. 47:530- 534 (1986). 10. Timbrell, V.: The Inhalation of Fibrous Dusts. Ann. Historical SVT TLVs N.Y. Acad. Sci. 132:255-273 (1965). 1974-1996: TLV-TWA. 10 mg/m® — Mineral wool fiber 11. Lippmann, M.: Effects of Fiber Characteristics on 1978-1996: TLV-TWA. 10 mg/m’ — Fibrous glass dust Lung Deposition, Retention, and Disease. Environ. Health Perspect. S8;311-317 (1990). Continuous Filament Glass Fibers 12. Milby, T.H.: Wolf, C.R.: Respiratory Tract Irritation 1996: ProposedTLV-TWA. 1 f/cc; Respirable particulate; from Fibrous Glass Inhalation. J, Occup. Med, TLV-TWA. 5 mg/m“: Inhalable particulate: A4. Not 11:409-410(1969). Classifiable as a Human Carcinogen 13. Lippmann, M.; Man-Made Mineral Fibers (MMMF): 1997-present TLV-TWA. 1 f/cc; Respirable particulate; Human Exposures and Health Risk Assessment. TLV-TWA, 5 mg/m’: Inhalable particulate: A4 Toxicol. Ind. Health 6:225-246 (1990). Glass Wool, Rock WooK Slag Wool, and Spedal-Purpose 14. Stanton, M.F,; Wrench.C.: Mechanisms of Glass Fibers Mesothelioma Induction with Asbestos and Fibrous Glass. J. Natl. Cancer Inst 48:797-822 (1972). 1996: Proposed TLV-TWA, 1 floci'; F3, Animal 15. Pott, F.; SchlipkSter, H.W.; et al.: New Results from Carcinogen with Unknown Relevance to Humans Implantation Experiments with Mineral Fibres. In: 1997-present TLV-TWA, 1 f/cc*: A3 Biological Effects of Man-Made Mineral Fibres. Vol. Rebactory Ceramic Fbars 2, pp. 286-302. Proceedings of a WHO/IARC 1996; Proposed F2, Suspected Human Carcinogen (TLV Conference, Copenhagen, Denmark, 20-22 April is under further review. A value no greater than 0.5 1982. World Health Organization, Regional Office for Hoc or less than 0.1/cc will be considered, based upon Europe, Copenhagen (1984). data currently available.) 16, Wagner, J.C,; Berry, G.B.: et al.: Animal Experiments 1998: Proposed TLV-TWA. 0.1 f/cc’: A2 with MMM(V>F — Effects of Inhalation and 2000: Proposed TLV-TWA. 0.2 f/cc'; A2 Intrapleural Inoculation in Rats. In: Biological Effects 2001: TLV-TWA, 0.2 f/cc'; A2 of Man-Made Mineral Fibres, Vol. 2. pp. 209-233. Proceedings of a WHO/IARC Conference. Respirable = length > 5 pm; aspect ratio > 3:1; as determined by Copenhagen, Denmark, 20-22 April 1982. World the membrane fitter method at 400-450x: magnification {4-mm Health Organization, Regional Office for Europe, objective) using phase-oomras! illumination. Copenhagen (1984). 17. McConnell, E.E.: Synthetic Vitreous Fibers — Inhalation Studies. ReguIaL Toxicol. Pharmacol. References 20(3);S22-S34 (1994), 1. International Programme of Chemical Safety: Man- 18. Morgan, A.; Davis, JA; et al.: Effect of Chemical Made Mineral Fibres. Environmental Health Criteria Composition on the Solubility of Glass Fibres in vivo 77. IPCS, World Health Organization, Geneva and in vHm. Ann. Occup, Hyg. 3S(Suppl. 1):609-617 (1988). (1994). 2. Vu, V.T.: Health Hazard Assessment of Nonasbestos 19. Morgan, A.; Holmes, A: The Deposition of MMMF in Fibers. Health and Environmental Review Division. the Respiratory Tract of the Rat, Their Subsequent Office of Toxic Substances, U.S. Environmental Clearance. Solubility in vivo and Protein Coating. In; Protection Agency, Washington. DC (1988). Biological Effects of Man-Made Mineral Fibres, Vol. 3. Pundsack, F.L.: Fibrous Glass: Manufacture, Use, 2, pp. 1-17. Proceedings of a WHO/IARC and Physical Properties. In; Occupational Exposure Conference. Copenhagen. Denmark. 20-22 April to Fibrous Glass; A Symposium, pp. 11-18. DHEW 1982, World Health Organization, Regional Office for (NIOSH) Pub. Wo. 76-151; NTIS Pub. No, PB-258- Europe, Copenhagen (1984). 869. National Technical Information Service, 20. Musselman, R.P.; Miller, W.C.; et al.: Biopersistences Springfield, VA (1976). of Man-Made Vitreous Fibers and Crocidolite Fibers 4. International Labour Office: Encyclopaedia of in Rat Lungs Following Short-Term Exposures. Occupational Health and Safety. ILO, Geneva (1983). Environ. Health Perspect. 102(Suppl. 5):139-143 5. Thermal Insulation Manufacturers Association. Inc. (1994). (TIMA): Nomenclature of Man-Made Vitreous Fibers: 21. Musselman, R.P.; Miller, W.C.; et al.; Biopersistences Nomenclature. Chemistry and Physical Properties. of Crocidolite Versus Man-Made Fibers in Rat Lungs TIMA, (March 1,1993). Following Brief Exposures. In; Toxic and 6. Assuncao, J.; Com. M.: The Effects of Milling on Carcinogenic Effects of Solid Particles in the Diameters and Lengths of Fibrous Glass and Respiratory Tract U. Mohr, J. Mauderty. and G. Chrysotile Asbestos Fibers. Am. Ind. Hyg. Assoc. J. Oberdorster, Eds. Ilsi Press. Washington. DC (1994), 36(11): 811-819 (1975). 22. Forster. H.: The Behaviour of Mineral Fibres in
2001 &ACGIH Synthetic Vitreous Fibers - 13
CITY_21MC100_011074987
NYC-WTC_000289649
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000289613
Narrative on health concerns and rationale for sampling dust and air post-9/11.
5 shared non-person entities · 1 shared topics · similarity 0.916
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318625
Overview of TEM vs optical microscopy for asbestos fiber measurement and historical context.
8 shared non-person entities · 1 shared topics · similarity 0.915
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000337538
Academic article on TEM detection limits for asbestos fibers and regulatory context.
8 shared non-person entities · 1 shared topics · similarity 0.913
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000301400
HSDB compilation entry on asbestos manufacturing, use, and properties.
13 shared non-person entities · 1 shared topics · similarity 0.911
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353784
DOHMH/ATSDR air and dust sampling results around 400 Chambers Street residences.
6 shared non-person entities · 1 shared topics · similarity 0.899
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000306672
Discussion on TEM vs optical microscopy for asbestos fiber detection and history.
8 shared non-person entities · 1 shared topics · similarity 0.916
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000437306
Lab report discussing TEM vs optical microscopy and regulatory asbestos limits.
8 shared non-person entities · 1 shared topics · similarity 0.914
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000307170
Discussion on TEM detection of asbestos fibers and regulatory limits referenced.
8 shared non-person entities · 1 shared topics · similarity 0.913
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000178388
Comprehensive report on airborne and dust exposures in Lower Manhattan following the September 11 attacks, published by the Department of Health.
12 shared non-person entities · 1 shared topics · similarity 0.900
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302730
Background on risk concepts, unit risk, and IRIS limitations related to asbestos exposure.
3 shared non-person entities · 1 shared topics · similarity 0.897
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000306681
Full method 7400 for asbestos and other fibers; exposure standards referenced.
6 shared non-person entities · 1 shared topics · similarity 0.896
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000450586
PCM asbestos method overview and regulatory limits for fibers.
6 shared non-person entities · 1 shared topics · similarity 0.896
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000146129
Correspondence from NYC Corporation Counsel providing comments on excerpts of a draft EPA evaluation report regarding the WTC response.
Similarity score 0.959 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320259
Draft report on potential exposures to airborne and settled surface dust in residential areas.
Similarity score 0.959 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149537
Instructions and sections for collecting sample location data from a specific building interior.
Similarity score 0.957 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362040
City data extract; WTC health and environmental services data.
Similarity score 0.957 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243169
Department memo referencing 9/11 toxic hazards at Ground Zero site.
Similarity score 0.955 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445524
Lab image sample fragment from NYC WTC file; city labeling present.
Similarity score 0.955 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000306672
Discussion on TEM vs optical microscopy for asbestos fiber detection and history.
Similar indexed content
NYC-WTC_000289613
Narrative on health concerns and rationale for sampling dust and air post-9/11.
Similar indexed content
NYC-WTC_000318625
Overview of TEM vs optical microscopy for asbestos fiber measurement and historical context.
Similar indexed content
NYC-WTC_000437306
Lab report discussing TEM vs optical microscopy and regulatory asbestos limits.
Similar indexed content
NYC-WTC_000307170
Discussion on TEM detection of asbestos fibers and regulatory limits referenced.
Similar indexed content