Mr. Bernard P. Orlan March 12, 2002
Indoor Air Quality Assessment Page 4
P. S. 150M ATC Project No. 15-19125-0289
* Tlie measurements made during this assessment were instantaneous read:ings, the NPAAQS is
a 24-hour average.
TVOCSC^icen^tions
TVOCs were not detected anywhere inside the building (0.0 ppm). The outdoor TVOC
concentration was also 0.0 ppm.
OBSERVATIONS
During this assessment, ATC noted the following:
• There was construction work going on in the plaza;
• The school building was occupied at the time of the assessment;
• No smoke odor was detected in the building;
FINDINGS
Based on the real-time measurements, the following findings are presented:
1. Concentrations of CO, CO2 and TVOCs were within applicable standards and guidelines;
2. None of the PM2.5 measurements were above the NPAAQS of 65 pg/m^ or above the
USEPA recommended PM2.5 concentration of 40 pg/m^ for sensitive individuals and
children.
3. One (1) of the temperature measurements was above the range of 68 to 750 p (;p 50 percent
relative humidity) recommended by ASHRAE Standard 55-1992 during the heating season
(wintertime conditions).
4. All measurements of relative humidity were below the ASHRAE recommended range of 30
to 60 percent for occupant comfort.
It is our pleasure to provide these indoor air quality services to the New York City Board of
Education. If you have any questions about this report, please call (212) 353-8280, extension
211 or 212.