Recommendations for Sampling Buildings with Residential Use-CONCEPTS for use near WTC DRAFT ATSDR/DHAC Version 1, Sept 25, 2001
1. Focus/Priorities of sampling The selection of priority residential areas should be decided upon by NYC DOH, or by someone else on the scene with the concurrence of NYCDOH. Selection needs to be based on worst-case scenario(s) first, which will likely involve a visual determination (e.g., visible dust in lobby area, broken windows, dust along roadways and sidewalks). Likely worst-case residential areas would seem to be: A. Residential areas closest (adjacent) to the WTC B. Residential areas where contaminant track-in from debris fallout or from Search/ Rescue/Removal vehicles have spread dust
Once a few worst-case areas have been selected, then the suggested sampling approach (see II) can be pursued. If results of sampling in worst-case locations indicate no contaminants present at levels of health concern, then residential sampling should be considered only on a case-by-case basis (e.g., citizen complaint followed by a visual inspection).
If results in worst-case locations show contaminants at levels of concern, a thorough cleaning (these instructions need to be developed) should follow and the locations should be re-sampled. If the post-cleaning round of sampling indicates successful remediation, then prior to sampling any additional residential locations (e.g., residential areas that also meet “worst case” or those on the tier below “worst case”) a thorough cleaning should be conducted. If post-sampling confirms that contaminants are below levels of health concern, then as other residential areas are cleaned, post-cleaning sampling should only occur periodically as a quality assurance check of cleaning effectiveness.
IL Sampling Approach ATSDR suggests that sampling should focus on asbestos (PCM and PCMe), respirable silica, and inhalable and respirable airborne particulate matter (TSP, PMl 0, and PM2.5). Sampling should focus on common/high traffic areas of the building (e.g., lobbies, front entryways). These areas should also be representative of worst case conditions for contaminant track-in.
If the building is unoccupied, aggressive indoor air sampling should be conducted. If the building is occupied, air sampling should be conducted with the building HVAC system in continuous operation.
Floor dust sampling should be conducted using EPA’s Environmental Response Team (ERT) SOP (HEPA vacuum). Location of sample and area sampled are required information to be collected. Samples should be analyzed for asbestos (via TEM as the detection limit for PLM is 1%); and respirable silica.
III. Action Levels Action levels will be developed for silica, PM, and vacuum dust samples. A format similar to the “ATSDR/CDC Asbestos Air Action Levels for World Trade Center Response” is anticipated.
CITY_21MC100_0 02953308
NYC-WTC_000288294
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000152788
A corrupted or unreadable document file containing garbled text and binary data.
10 shared non-person entities · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000176041
Draft document outlining the methodology and scope for environmental sampling of residential areas in Battery Park City following the WTC collapse.
10 shared non-person entities · similarity 0.946
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153241
Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.
8 shared non-person entities · similarity 0.941
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152814
Draft document outlining concepts and priorities for sampling buildings near the WTC to identify worst-case contamination scenarios.
9 shared non-person entities · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164417
Chain of custody records and emails forwarding the ATSDR residential and commercial interior sampling program draft.
8 shared non-person entities · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152801
Correspondence forwarding a revised indoor air sampling plan focusing on residential areas and concentric zones.
9 shared non-person entities · similarity 0.936
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250593
DOH evaluation document for health assessment in WTC-affected area.
8 shared non-person entities · similarity 0.935
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152790
Plan for ATSDR indoor air sampling; revised plan noted.
9 shared non-person entities · similarity 0.935
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250606
DOH page showing page 1 of sampling protocol for WTC residential areas.
7 shared non-person entities · similarity 0.935
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250536
ATSDR/DHAC draft on ambient dust evaluations around WTC areas.
9 shared non-person entities · similarity 0.934
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000235065
Draft environmental sampling protocol for residential areas near the World Trade Center developed by ATSDR/DHAC in October 2001.
8 shared non-person entities · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317962
Lab evaluation of residential dust near WTC for asbestos and related contaminants (draft).
9 shared non-person entities · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000152812
Draft document providing concepts and priorities for selecting buildings to sample for contaminants following the World Trade Center collapse.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152788
A corrupted or unreadable document file containing garbled text and binary data.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000176041
Draft document outlining the methodology and scope for environmental sampling of residential areas in Battery Park City following the WTC collapse.
Similarity score 0.978 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250593
DOH evaluation document for health assessment in WTC-affected area.
Similarity score 0.977 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302176
Residential impact and WTC area dust sampling discussion in ATSDR/DHAC draft, Oct 2001.
Similarity score 0.975 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320050
Draft ATSDR/DHAC evaluation of ambient and indoor dust near WTC with asbestos data.
Similarity score 0.975 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000152788
A corrupted or unreadable document file containing garbled text and binary data.
Similar indexed content
NYC-WTC_000176041
Draft document outlining the methodology and scope for environmental sampling of residential areas in Battery Park City following the WTC collapse.
Similar indexed content
Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.
Similar indexed content
NYC-WTC_000152814
Draft document outlining concepts and priorities for sampling buildings near the WTC to identify worst-case contamination scenarios.
Similar indexed content
NYC-WTC_000164417
Chain of custody records and emails forwarding the ATSDR residential and commercial interior sampling program draft.
Similar indexed content