Kelpin, Gerry IIIlB lllli From: Fox, Janet R Sent: Tuesday, September 18, 2001 9:51 AM . To: '[email protected]'; '[email protected]'; '[email protected]'; '[email protected]'; '[email protected]'; '[email protected]'; '[email protected]'; '[email protected]'; '[email protected]'; '[email protected]'; '[email protected]'; '[email protected]' Cc: Louie, Eddy; Chang, Angel Subject: FW: asb wtc

DATA SUMMARY as of 9/18/01 7:15 am.

On September 11, Con Edison EHS Department initiated a Sampling Plan for asbestos bulk sampling, area monitoring and personnel monitoring. Sampling and analysis is being performed by our company lab and outside labs, ATC, Air Tech and Sci-Lab under the direction of the Industrial Hygienists of Corporate EHS.

The following is a summary of the data to date:

Bulk Sample results: 36 samples taken samples range fromND.to 1.5 % asbestos 34 samples < then 1.0% asbestos 2 > 1 % asbestos were 1.3% and 1.5% samples >1.0 % located at West St. and Watt and West St. south of Vessy St.

Area Samples: 15 samples taken sample range ffom<0.01 to 0.232f/cc sample duration from 30 to 208 minutes 7 of 22 Samples > O.OIf/cc 1 of 7 Samples > 0.01 was 0.232 f/cc (PCM) TEM on this sample was 0.223 s/cc 7 of 22 Samples at 0.01 8 of 22 Samples at < 0.01 all area samples from 9/17/01 , are < 0.01 f/cc (PCM)

Personal Samples: 192 samples taken sample range from <0.01 to 2.114 f/cc (PCM) sample duration from 30 to 335minutes 144 samples of 192 were < O.lf/c (PCM) 48 samples of 192 were >0.1 f/cc (PCM) 1 sample >1.0 f/cc was 2.114 f/cc (PCM) elevated levels >0.1 f/cc for work: o walking - 0.03 to 0.66 f/cc o pulling cable - 0.1 to 2.114 f/cc o turning valves - 0.032 to 0.359 f/cc o cut/cap gas main - 0.026 to .131 f/cc

CITY_21MC100_002953147

NYC-WTC_000288263

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000288263Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000288264

Sampling plan for asbestos bulk sampling, area monitoring and personnel monitoring at Con Edison site.

Similar indexed content

NYC-WTC_000288265

Summary of bulk sample results from asbestos sampling at Con Edison EHS area.

Similar indexed content

NYC-WTC_000187540

Internal data summary of bulk sampling results for asbestos at Con Edison EHS sampling plan.

Similar indexed content

EPA air sampling status report, Mar 2002

NYC-WTC_000196433

Status report on asbestos air sampling results from the EPA indicating samples were below TEM AHERA standards in March 2002.

Similar indexed content

Compare copies and versions →