Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Centers for Disease Control and Prevention
National Institute for Occupational Safety and Health
Interim Bulk and Air Sampling Report
Wednesday, September 19, 2001
Investigators from the National Institute for Occupational Safety and Health (NIOSH) collected bulk and air
samples in areas immediately adjacent to the debris pile and on personnel actively involved in rescue efforts on
or in the vicinity of the debris pile to characterize potential and actual occupational exposures. Below are the
interim sampling results for Wednesday, September 19, 2001.
Bulk Samples
Asbestos
• 27 bulk samples were collected from undisturbed loose material within the restricted area
o Most samples indicated less than 1% asbestos (two contained between 1 and 3% asbestos)
Cry^stalline Silica
• 27 bulk samples were collected from undisturbed loose material within the restricted area
o All samples contained quartz, typically in amounts less than 5%, although one sample was as
high as 18% quartz
o None of the samples contained cristobalite
Metals
• 27 bulk samples were collected from undisturbed loose material within the restricted area
o Nothing of concern was found regarding metal analysis
Air Samples
Asbestos
• 3 personal air samples and 3 area air samples were collected by NIOSH investigators
o All task-based concentrations were below 0.05 fibers/cc as determined by TEM analysis
• Additional air samples were collected by NYDOH contractors (26 personal and 4 area)
o Personal sample 8-hour time-weighted average concentrations were below 0.05 fibers/cc as
determined by PCM
o 22 personal samples were analyzed by TEM; most were non-detectable (4 were <0.016 fibers/cc)
o Area sample results were below 0.04 fibers/cc as determined by PCM
Carbon Monoxide
• 5 real-time personal breathing zone samples were collected for carbon monoxide
o All 8-hour time-weighted average concentrations were below 3 ppm
o A single peak of 79 ppm was observed on a city transit worker
Freon 22
• 5 area air samples were collected for Freon 22
o Concentrations of Freon 22 on all samples were below detectable limits
Metals
• 17 air samples were collected for metals (7 personal and 10 area)
o Nothing of concern was found regarding metal analysis
Total Dust
• 17 air samples were collected for total dust (7 personal and 10 area)
o Personal sample 8-hour time-weighted average concentrations were below 1.0 mg/m^
o Area sample concentrations were below 1.7 mg/in '
Volatile Organic Compounds (VOCs)
• 6 air samples were collected on thermal desorption tubes (used as a screening technique)
o Compounds identified included benzene, toluene, and polynuclear aromatic hydrocarbons which
have been attributed to products of combustion
o Concentrations of VOCs on all samples were well below established limits
• 19 air samples were collected with charcoal adsorbent tubes
o Concentrations of VOCs on all samples were below detectable limits
K.M. Wallingford lO/ll/OI
CITY_21MC100_002967964
NYC-WTC_000287821
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000287821Source: NYC Law Department, mirrored locally