Centers for Disease Control and Prevention National Institute for Occupational Safety and Health Interim Bulk and Air Sampling Report Wednesday, September 19, 2001

Investigators from the National Institute for Occupational Safety and Health (NIOSH) collected bulk and air samples in areas immediately adjacent to the debris pile and on personnel actively involved in rescue efforts on or in the vicinity of the debris pile to characterize potential exposures. Below are the interim sampling results for Wednesday, September 19, 2001.

Bulk Samples Asbestos • 27 bulk samples were collected from undisturbed loose material within the restricted area o Most samples indicated less than 1% asbestos (two contained between 1 and 3% asbestos) Crystalline Silica • 27 bulk samples were collected from undisturbed loose material within the restricted area o All samples contained quartz, typically in amounts less than 5%, although one sample was as high as 18% quartz o None of the samples contained cristobalite Metals • 27 bulk samples were collected from undisturbed loose material within the restricted area o Nothing of concern was found regarding metal analysis

Air Samples Asbestos • 3 personal air samples and 3 area air samples were collected by NIOSH investigators o All task-based concentrations were below 0.05 fibers/cc as determined by TEM analysis • Additional air samples were collected by NYDOH contractors (26 personal and 4 area) o Personal sample 8-hour time-weighted average concentrations were below 0.05 fibers/cc as determined by PCM O 22 personal samples were analyzed by TEM; most were non-detectable (4 were <0.016 fibers/cc) o Area sample results were below 0.04 fibers/cc as determined by PCM Carbon Monoxide • 5 real-time personal breathing zone samples were collected for carbon monoxide o All 8-hour time-weighted average concentrations were below 3 ppm o A single peak of 79 ppm was observed on a city transit worker Metals • 17 air samples were collected for metals (7 personal and 10 area) o Nothing of concern was found regarding metal analysis Total Dust • 17 air samples were collected for total dust (7 personal and 10 area) o Personal sample 8-hour time-weighted average concentrations were below 1.0 mg/m^ o Area sample concentrations were below 1.7 mg/m^ Volatile Organic Compounds (VOCs) • 6 air samples were collected on thermal desorption tubes (used as a screening technique) o Compounds identified included benzene, toluene, and polynuclear aromatic hydrocarbons which have been attributed to products of combustion o Concentrations of VOCs on all samples were well below established limits • 19 air samples were collected with charcoal adsorbent tubes o Concentrations of VOCs on all samples were below detectable limits . K,M. Wallingford 10/4/01

CITY_21MC100_008906362

NYC-WTC_000187724

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000187724Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →