NYC 9/11 Public Portal Document
Inorganic Acids OSHA has taken approximately 49 samples for inorganic acids such as hydrochloric, phosphoric, and
sulfuric acids. One sample for sulfuric acid was found to exceed OSHA’s permissible exposure limit
(PEL) of 1 mg/m’. Additional sampling results are pending.
Oxides of Nitrogen/
Sulfur: Sampling on grappler operators on the rubble pile, and on employees at the truck wash stations revealed
trace levels of nitric oxide and nitrogen dioxide. This was repeated (1) sample, now that the wash
station is been enclosed. SO, personal and area results were found to be below OSHA limits.
Metals: OSHA has taken 784 samples (excluding bulk and blank samples) to monitor worker exposures to dusts,
fumes, oxides, and other compounds of metals such as antimony, beryllium, chromium, cobalt, copper,
iron, lead, manganese, molybdenum, nickel, vanadium, zinc, cadmium, magnesium, and arsenic.
Results from these samples are generally well below the applicable OSHA limits. However, torch
cutting and burning structural steel at the rubble pile have resulted in instances of overexposures as
follows: copper (12); iron oxide (23); lead (12); and cadmium (2). Accordingly, OSHA is
recommending that workers engaged in these operations wear appropriate respirator)' protection.
Mercury OSHA has taken 161 air samples for inorganic mercury. Results for 161 of those air samples have been
received and no mercury was detected. Also, 36 bulk samples previously collected from rubble were re
analyzed for mercury and none was detected. Additionally, 10 bulks were taken on 1/3, with one (1)
sample detecting mercury at 0.9ppm and nine (9) samples being non-detected. 8 bulk samples were
taken on 1/8, and 7 bulk samples were taken on 1/9, with results pending.
Ionizing Radiation: A survey of the rubble pile was conducted on 10/22-10/23 to check for latent radiation with particular
attention to alpha radiation. Preliminary results show no elevated levels.
Dioxins: OSHA has taken 15 dioxin samples in the plume over hot spots in (and around the perimeter of) the
rubble pile. Dioxin levels detected around the perimeter are lower than those found directly over the
pile. To date, only one sample taken on the rubble pile showed dioxin levels which exceeded
background levels. Dioxins are considered collectively as suspect human carcinogens. OSHA does not
have a PEL for dioxins.
Polynuclear Aromatic
Hydrocarbons OSHA has taken 132 samples. The majority of the samples have not shown the presence of
benzo(a)pyrene and/or one or more of five additional fused polycyclic hydrocarbons: anthracene,
acridine, pyrene, chrysene and phenanthrene. Sample results to date have identified eight samples
which reached or exceeded OSHA’s coal tar pitch volatile FEL of 0.2mg/m’. These personal samples
were taken on the pile on iron workers and grappler operators. OSHA continues to strongly
recommend the use of respiratory protection when working on the rubble pile.
Freon R-22,
Hydrogen Fluoride
& Phosgene: OSHA has taken a total of 196 samples for Freon R-22 (chlorodiflouromethane), hydrogen flouride, and
phosgene. Only one Freon sample resulted in a detectable level of 6.4 p pm during the transfer of Freon
from the auxiliary chiller, and all other samples were none-detected. OSHA does not have an exposure
limit for Freon R-22. (The NIOSH REL for Freon is lOOOppm..) Sampling for the decomposition
products of Freon R-22, hydrofluoric acid (HF) and phosgene showed no detectable levels.
Page 2 of
CITY_21MC100_008111676
NYC-WTC_000287793
OCR can misread numbers and units. Confirm readings against the page image before using them.