OSHA SAMPLING RESULTS SUMMARY AS OF 1/8/02
Asbestos; A total of 810 samples (excluding bulk and blank samples) for asbestos have been taken. From 9/13 -
9/21,177 samples were taken in the financial district. They were taken on OSHA personnel as they
. walked within certain predetermined zones. Results revealed asbestos concentrations ranging from ND
(none detected) to .037 f/cc., well below OSHA’s permissible exposure limit (PEL) of 0.1 free. After
9/21, sampling focused on the rubble pile and those workers working on or immediately next to it. 108
of the samples analyzed exceeded OSHA’s limit via PCM analysis. However, upon further analysis
using discriminating counting methods and/or TEM analysis, the number of asbestos fibers found
dropped dramatically to below detectable levels or well below . 1 free.
Carbon Monoxide: A total of 98 personal samples of workers on the rubble pile showed results ranging from 1 ppm to 34
ppm which are well below the OSHA permissible exposure limit of 50 PPM.
Noise: OSHA is monitoring the noise exposures of employees who perform (or work near) noisy operations
such as jack hammering and drilling. To date the 79 samples collected indicate that ernployee noise
exposures range from 73.7 dBA to 94.5 dBA. One personal sample and one area sample taken during
core drilling operations have exceeded the applicable permissible exposure limit of 90 dBA.
Accordingly, OSHA continues to recommend the use of appropriate hearing protection in noisy
operations.
Total Dust (PNOR) A total of 92 samples (excluding bulk and blank samples) for total dust in and around the rubble pile
were taken. Two samples were found to be in excess of the PEL for Total dust (15mg/m3). The
highest exposure was found oh one operator who was exposed at approximately 4X PEL.
Respirable
Silica: The overwhelming majority of 375 silica samples (excluding bulk and blank samples) show no
detectable levels of airborne silica However, twenty one exposures exceeded the PEL. The highest
sample result was approximately twenty one times the OSHA limit (pre-drillers working on the slurry
or “bathtub” wall). The other twelve elevated exposures were approximately one to seven times the
OSHA limit These exposures occurred during: 1) jack hammering, 2) rubble removal and loading
operations near the Winter Garden; 4) during the breaking up of concrete in the pit; 5) while core
drilling the concrete slurry wall, and 6) while chipping concrete with power tools during demolition
activities at 7 WTO’s parking garage. Most of the work areas where apparent overexposures to silica
occurred were in the rubble pile; an area where OSHA continues to encourage the use of respiratory
protection.
Organic
Compounds: OSHA has taken 506 samples (excluding bulk and blank samples) for (VOCs) such as acetaldehyde,
acrolein, acrylonitrile, benzene, 2-butanone, carbofiirans, PCBs, ethyl benzene, formaldehyde. Freon
R-22 (chlorodiflouromethane), hexone, isocyanates (e.g. MDI, TDl), perchloroethylene, phosgene,
styrene, toluene, 1-3 butadiene,'trichloroethylene, vinyl chloride, glutaraldehyde, and xylene.
Screening samples initially showed elevated levels of some organic chemicals resulting from the fires
burning in the rubble pile. Subsequent personal and area samples show worker exposure levels to be
below OSHA limits. However, one personal sample result for a benzene sample taken was found to be
at the 8-hr. OSHA Allowable Limit concentration of 1 ppm. This was found on a backhoe operator
moving debris on 10/7/01. See information below for polynuclear aromatics. Freon R-22, phosgene
and dioxin.
Page 1 of 2
CITY_21MC100_006533010
NYC-WTC_000209193
OCR can misread numbers and units. Confirm readings against the page image before using them.