EPA asbestos air sampling locations report, Dec 2001

Machine-extracted title · confidence 41%

EPA report detailing NYC ER asbestos sampling locations and results.

NYC-WTC_000287515–000287518
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

NYC / ER (Nov 30) - Particulate Monitoring (TEOM PM 2 5) o Park Row (Site 1) - 24-hr average concentration for this period was 20.16 ug/m^. o Manhattan Boro Community College (Site 2) - 24-hour average concentration for this period was 23.48 ug/nr’. o Coast Guard Building - Battery Park (Site 3) - 24-hour average concentrations for this period was 18.80 ug/n^. o Wall Street - 24-hour average concentrations for this period was 19.01 ug/nr . o All readings below the National Ambient Air Quality Standard for PM, 5 (65 ug/m^). NYC / ER (Nov 28) - Particulate Monitoring (TEOM PM,o)

o Wall Street - 24-hour average concentrations for this period was 39.81 ug/m\ o All readings below the National Ambient Air Quality Standard for PM,o (150 ug/m’). NYC / ER (Nov 29) - Particulate Monitoring (TEOM PM,o)

o Wall Street - 24-hour average concentrations for this period was 36.46 ug/ni'. o All readings below the National Ambient Air Quality Standard for PM,o (150 ug/m '). NYC / ER (Nov 30) - Particulate Monitoring (TEOM PM,o)

o Wall Street - 24-hour average concentrations for this period was 31.02 ug/n^. o All readings below the National Ambient Air Quality Standard for PM,o (150 ug/mQ.

NYC / ER (Nov 30) - Particulate Monitoring (Dataram) o Particulate levels noted at three locations (Stations L, N, R) were below the OSHA TWA. o Instruments operated approximately 8 hours o Station L values ranged from 39.3 to 318.5 ug/m^ with an average of 80.0 ug/m\ o Station N values ranged from 40.8 to 357.2 ug/m^ with an average of 76.7 ug/m\ o Station R values ranged from 52.0 to 255.3 ug/m’with an average of 81.3 ug/m\ NYC / ER (Dec 1) - Particulate Monitoring (Dataram) o Particulate levels noted at three locations (Stations L, N, R) were below the OSHA TWA. o Instruments operated approximately 8 hours o Station L values ranged from 53.8 to 243.7 ug/m’with an average of 90.5 ug/m\ o Station N values ranged from 0.5 to 99.3 ug/m’ with an average of 30.8 ug/mh o Station R values ranged from 1.1 to 87.5 ug/m" with an average of 31.4 ug/m'. NYC / ER (Nov 30) - Volatile Organics (Mobile Laboratory) o Benzene exceeded OSHA TWA PEL (1 ppm) at two locations (North l ower and South Tower) on the debris pile in the plume at ground level. o Both of the other samples (Wash Tent and Austin Tobin Plaza) did not note any benzene above the detection limit (20 ppbv).

CITY_21MC100_002417090

NYC-WTC_000287517

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000287517Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

Air sampling locations, Oct 2001 · Box unavailable

NYC-WTC_000321273

EPA asbestos air sampling at NYC/ER and NJ/ER with most results below TEM AHERA; one location not sampled and one above standard noted.

7 shared non-person entities · 1 shared topics · similarity 0.982

machine-extracted · confidence unavailable · Check page ↗

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000321195

Asbestos air sampling results at NYC/ER and Fresh Kills; notes on pending results and malfunctions.

Similar indexed content

NYC-WTC_000321165

Asbestos air sampling results; some exceedances at indoor/perimeter locations.

Similar indexed content

Asbestos air sampling results, NYC ER/Dec 2001

NYC-WTC_000331910

Air sampling results for asbestos at NYC Emergency Response locations, showing all samples below TEM AHERA standard and notes on low volumes or access issues.

Similar indexed content