NYC / ER (Dec 4) - Particulate Monitoring (TEOM PM 2.5)
o Park Row (Site 1) - 24-hr average concentration for this period was 25.69 ug/m\
o Chambers St./West St. (Site 2) - 24-hour average concentration for this period was 23.14
ug/m^.
o Coast Guard Building - Battery Park (Site 3) - 24-hour average concentrations for this
period was 24.37 ug/in\
o Wall Street - 24-hour average concentrations for this period was 25.17 ug/m\
o All readings below the National Ambient Air Quality Standard for PM2.5 (65 ug/mQ.
NYC / ER (Dec 5) - Particulate Monitoring (TEOM PM 2.5)
o Park Row (Site 1) - 24-hr average concentration for this period was 26.22 ug/m\
o Chambers St./West St. (Site 2) - 24-hour average concentration for this period was 27.94
ug/m^.
o Coast Guard Building - Battery Park (Site 3) - 24-hour average concentrations for this
period was 23.65 ug/m\
o Wall Street - 24-hour average concentrations for this period was 24.77 ug/in^.
o All readings below the National Ambient Air Quality Standard for PMj 5 (65 ug/mQ.
NYC / ER (Dec 3) - Particulate Monitoring (TEOM PMio)
o Wall Street - 24-hour average concentrations for this period was 39.06 ug/m\
o All readings below the National Ambient Air Quality Standard for PMio (150 ug/m’).
NYC / ER (Dec 4) - Particulate Monitoring (TEOM PMk,)
o Wall Street - 24-hour average concentrations for this period was 46.77 ug/nt^.
o All readings below the National Ambient Air Quality Standard for PMjq (150 ug/mQ.
NYC / ER (Dec 5) - Particulate Monitoring (TEOM PM,o)
o Wall Street - 24-hour average concentrations for this period was 49.14 ug/m\
o All readings below the National Ambient Air Quality Standard for PM,o (150 ughnh.
NYC / ER (Dec 6) - Particulate Monitoring (Dataram)
o Particulate levels noted at three locations (Stations L, N, R) were below the OSHA TWA.
o Instruments operated approximately 6.5 hours.
o Station L values ranged from 5.9 to 134.8 ug/m^ with an average of 39.9 ug/m\
o Station N values ranged from 10.0 to 205.3 ug/m^ with an average of 32.6 ug/m\
o Station R values ranged from 0.1 to 104.7 ug/m’ with an average of 31.1 ug/m\
NYC / ER (Dec 6) - Volatile Organics (Mobile Laboratory)
o Benzene exceeded OSHA TWA PEL (1 ppm) at one location (North Tower) in the debris
area in the plume at ground level.
o 2 of the 3 other samples (Wash Tent and Austin Tobin Plaza) did not note any benzene
above the detection limit (20 ppbv).