NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos air sampling results, Staten Island landfill

Machine-extracted title · confidence 41%

NYC response: asbestos air sampling at Staten Island landfill; dates 12/01/01.

NYC-WTC_000287485
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

Z z O o co S NYC Response o Asbestos Air Sampling Results for Staten Island Landfill ■D c I o Sampling Date and Times: 12/01/01 0815 to 2242*"’ Data Validation Date: 12/03/2001 CT o o o' KJ PCM by NIOSH 7400 00 TEM AHERA) ■D O Sampling Sampling Sample Structures (#) 3. 03 00 Date Sample No. Location Volume* Matrix f/mm^ f/cc 5p S/mm^ S-f/cc“ cn Air^ O 12/01/01 LF01294 P-1 720 <7.0 <0.004 ___ 0__ 0 <8.75 <0.0047 12/O17o1 o LF01295 P-2 572 Air <7.0^ <0.005 0 0 <8.75 <0.0059 o 12/01/01 LF01296 P-3 Air ’ c 720 <7.0 <0.004 0 0 <8.75 <0.0047 LFOT297 3 12/01/01 P-4 720 Air <7.0 " <0.004 ___ 0 6 <8.75 <0.0047 CD 12/01/0r LF01298 P-5 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 12/01/01 LF01299 P-6 720 Air ’ * <7^0 <0.004 ___ 0_^ 0 <8.75 <0.0047 12/01/01 LF01300 P-7 720 Air <7.0 <0.004 ___ 0 " ’.. b <8.75 <0.0047 12/01/01 LF01301 P-8 720 Air <0.004 b 0 <8.75 <0.0047 12/01/01^ LF01302 W-11 720 Air <0.004 ___ 0_ 0 <8.75 <0.0047 12/01/01 LFbl303 W-12A 720 Air <7.0~~ <0.004 b_ “~0 <8.75 <0.0047 l^oT/oi LF01304 W-12B 720 Air “<7.0”^ <0.004 0 ' 0 <8.75 <0.0047 12/01/01 LF01305 B-13 653 Air <7.0 <0.004 0 0 <7.87 <0.0046 12/01/of LF01306 B-14 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 12/01/01 ' LF0130/^’ T-15 1468 Air 11.46 0.003 0 ” <15.75 <0.0041 12/01/01 LF01308 T-16 495 Air 10.19 0.008 0 <6.06 <0.0047 12/01/01 LF01309 0-17 720 Air <7.0 <0.004 ___ 0___ 0 <8.75 <0.0047 12/01/01 LF01310 0-18 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 12/01/0? LFbl311 0-19 676 Air <7.0 <0.004 6 0 <8.75 <0.0050 12/01/01 LF01312 MPHS-20 720 Air <7.0 <0.004 0 <8.75 <0.0047 12/01/01 LF01313 Lot Blank 0 Air <7.0 n/a NA<"> NA® NA‘2> NA<^> 12/01/01 LF01314 Trip Blank 0 Air <7.0 n/a NA'"' NA<2> na<2> NA<2>

Key: * Sample volume (liters) is below recommended limit for the TEM method; volume is based on pump reading ** Structure (S) is roughly equivalent to fiber (f) *** Chrysotile

NA - Not analyzed due to overloading of particulates NA - Not analyzed for TEM n/a - Not applicable NC- Not collected - Sample LF01307, T-15, was collected on 12/02/01 at 0909 due to closing off of area during 12/01 evening hours. Sample pump ran continously during this period of time. o H k; I KJ NIOSH 7400: Fiber Analysis of Air samples via NIOSH 7400, Revision 3, Issue 2, 8/15/94 S Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) EPA 40CFR Part 763 (AHERA) o Standard criteria: EPA 40CFR Part 763 (AHERA): 0.01 fiber/cc (PCM), 70 S/mm? volume 1200 L, for 25 mm filter (TEM) O O I o o KJ

O', FK-12-01-01-am

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000287485Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →