o o i o NYC Response co

I o Asbestos Air Sampling Results for WTC Extended Network “0 c o Sampling Date and Time: 12/15/01 1200 to 2400 Data Validation Date: 12/19/2001 CT o ro o' oo "0 Ca5 PCM by NIOSH 7400 TEM AHERA) o oo ro Sampling Sampling Sample Structures (#) 9L Location Volume (Lf Matrix f/mm^ f/cc 0.5U-5U Sm S/mm^ S-f/cc‘ O Date Sample No. o o c 12/15/01 7093-18-0079 Park Row 1354 Air <7.0 <0.002 0 0 <16.00 <0.0045 3 o 12/15/01 7093-19-0079 Chamber St. 1314 Air <7.0 <0.002 0 0 <16.00 <0.0047 3

12/15/01 7093-20-0079 Coast Guard 1160*** Air <7.0 <0.002 0 0 <13.33 <0.0044 12/15/01 7093-15-0078 Manhattan PS #143 1440 Air <7.0 <0.002 0 0 <16.00 <0.0043 12/15/01 7094-09-0068 Bronx PS #154 1440 Air <7.0 <0.002 0 0 <16.00 <0.0043 12/15/01 7096-12-0073 Queens PS #199 1286 Air <7.0 <0.002 0 0 <16.00 <0.0048 12/15/01 7095-98-0075 Brooklyn PS #274 1440 Air <7.0 <0.002 0 0 <16.00 <0.0043 12/15/01 7097-18-0071 Staten Island PS #44 1440 Air <7.0 <0.002 0 0 <16.00 <0.0043

Key: ‘Structure (S) roughly equivalent to fiber (f) ** Sample volume is based on pump reading *** Sample volume is below recommended limit for TEM analysis **** Chrysotile NA’^’ - Not analyzed due to overloading of particulates NA*^’ - Not analyzed for TEM due to wet filter n/a- Not applicable NR - analysis not requested NS - Sample not submitted for analysis due to no sample volume

Q NIOSH 7400: Fiber Analysis of Air samples via NIOSH 7400, Revision 3, Issue 2, 8/15/94 i-< Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) EPA 40CFR Part 763 (AHERA) I Standard criteria: EPA 40CFR Part 763 (AHERA): 0.01 fiber/cc (PCM), 70 S/mm^, volume 1200 L, for 25 mm filter (TEM) I o o I o o

ext-12-15-01 pm co

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000287382Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000287458

NYC Response: asbestos air sampling results for WTC site, with date/time and analysis method.

Similar indexed content

Compare copies and versions →