Asbestos air results, WTC/Lower Manhattan, 12/09/01

Machine-extracted title · confidence 38%

NYC Response: Asbestos air sampling results for WTC, date 12/09/01.

NYC-WTC_000287376
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

z ■< z ■<

o o io NYC Response co

I o Asbestos Air Sampling Results for WTC Extended Network ■D c o Sampling Date and Time: 12/09/01 1200 to 2400 *** Data Validation Date: 12/13/2001 CT o ro o' oo ■D co PCM by NIOSH 7400 TEM AHERA) o 3. 03 o Sampling Sampling Sample Structures (#) Date Sample No. Location Volume (L)** Matrix f/mm^ f/cc 0.5m - Sp Su S/mm^ S~f/cc‘ o o o c 12/09/01 7093-18-0073 Park Row 1374 Air <7.0 <0.002 0 0 <16.00 <0.0045 3 CD 12/09/01 7093-20-0073 Coast Guard 1440 Air <7.0 <0.002 0 0 <16.00 <0.0043 12/09/01 7093-19-0073 BMCC 1132*** Air <7.0 <0.002 0 0 <13.33 <0.0045 12/09/01 7097-18-0065 Staten Island PS #44 1440 Air <7.0 <0.002 0 0 <16.00 <0.0043 12/09/01 7095-98-0069 Brooklyn PS #274 1192*** Air <7.0 <0.002 0 0 <13.33 <0.0043 12/09/01 7096-12-0067 Queens PS #199 1242 Air <7.0 <0.002 0 0 <13.33 <0.0041 12/08/01^®' 7094-09-0062 Bronx PS #154 1300 Air <7.0 <0.002 0 0 <16.00 <0.0047 12/09/01 7093-15-0072 Manhattan PS # 143 1440 Air <7.0 <0.002 0 0 <16.00 <0.0043

Key: *StructurG (S) roughly equivalent to fiber (f) ** Sample volume is based on pump reading *** Sample volume is below recommended limit for TEM analysis **** Chrysotile NR - analysis not requested NS - Sample not submitted for analysis n/a - Not applicable (a) - Sample 7094-09-0062, Bronx PS #154, was collected on 12/08/01 1200 to 2250

Q NIOSH 7400: Fiber Analysis of Air samples via NIOSH 7400, Revision 3, Issue 2, 8/15/94 H Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) EPA 40CFR Part 763 (AHERA) K I Standard criteria: EPA 40CFR Part 763 (AHERA): 0.01 fiber/cc (PCM), 70 S/mm^ volume 1200 L, for 25 mm filter (TEM)

I o o I o o

ext-12-09-01 pmrevi

CO

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000287376Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000287466

NYC DEP: asbestos air sampling results for WTC site with time window 12/02/01.

Similar indexed content

Compare copies and versions →