Ambient Air Sampling Locations
NYC / ER (Jan 5) - Asbestos Monitoring (Particulate Monitoring Stations)
o Monitoring sites include:
Park Row (Site 1)
Chambers St./West St. (Site 2)
Public School 154: 333 East 135*^ St. Bronx (Site 5)
Intermediate School 143: 511 West 182"‘* St.. Manhattan (Site 6)
Public School 274: 800 Bushwick Ave.. Brooklyn (Site 7)
Public School 44: 80 Maple Parkway. Staten Island (Site 8)
Public School 199: 3290 - 48**' Ave.. Queens (Site 9)
o During this period a total of 6 samples were collected from these monitoring sites.
o A sample was not collected from Site 5 since access to that location was not available.
o All of the samples were below the TEM AHERA standard.
NYC / ER (Jan 9) - Particulate Monitoring (Dataram)
o Particulate levels noted at three locations (Stations L, N, R) were below the OSHA
TWA.
o Instruments operated approximately 1 ‘A to 2 hours due to the weather conditions.
o Station L values ranged from 35.3 to 217.0 ug/m^with an average of 51.5 ug/m\
o Station N values ranged from 0.0 to 205.8 ug/m’with an average of 50.7 ug/m\
o Station R values ranged from 28.0 to 128.7 ug/m^ with an average of 42.0 ug/m\
NYC / ER (Jan 9) - Volatile Organics (Mobile Laboratory)
o Benzene did not exceed OSHA TWA PEL (1 ppm) at any of the four locations
monitored, including in the debris area at ground level.
o Benzene was not detected above the detection limit (20 ppbv) in 3 of the 4 locations
monitored (Washing Tent, Austin Tobin Plaza, and South Tower), including in the debris
area at ground level.
o 1,3-Butadiene was not detected in any of the samples above the detection limit (20 ppbv).
Direct Reading Instruments
NYC / ER (Jan 9)
o Nothing of significance reported in the limited monitoring conducted.
o Monitoring impacted by weather conditions.