NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos air sampling results, Staten Island landfill, Jan 2002

Machine-extracted title · confidence 42%

NYC response: asbestos air sampling at Staten Island Landfill; 01/14/02 collection times; PCM/N IOC 7400, TEM AHERA.

NYC-WTC_000287303
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

z Z o o co g NYC Response U 1^ Asbestos Air Sampling Results for Staten Island Landfill c CT o Sampling Date and Times. 01/14/02 0816 to 2230 Data Validation Date: 01/16/2002 o o' o ro U oo PCMbyNIOSH 7400 TEM AHERA) O 3. Ca5 Sampling Sampling Sample Structures (#) 03 O f/mm’ GO Date Sample No. Location Volume* Matrix f/cc O.Sp - Sp S/mm’ S-f/cc** O 01/14/02 LF02171 P-1 720 Air <7.0 <0.004 0 0 <7.87 <0.0042 o o 01/14/02 LF02172 P-2 422 Air <7.0 <0.006 0 0 <8.75 <0.0080 c 01/14/02 LF02173 P-3 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 3 CD 01/14/02 LF02174 P-4 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 01/14/02 LF02175 P-5 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 01/14/02 LF02176 P-6 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 01/14/02 LF02177 P-7 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 01/14/02 LF02178 P-8 210 Air <7.0 <0.013 0 0 <8.75 <0.0160 01/14/02 LF02179 W-11 720 Air 26.75 0.014 0 0 <8.75 <0.0047 '01/14/02 LF02180 W-12A 720 Air 11.46 0.006 0 8.75 0.0047 01/14/0^ LF02181 W-12B 720 Air <7.0 <0.004 2*.. 0 17,50 0.0094 01/14/62 LF02182 B-13 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 01/14/02 LF02183 B-14 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 01/14/02 LF02184 T-15 720 Air 7.64 0.004 0 0 <8.75 <0.0047 01/14/02 LF02185 T-16 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 01/14/02 LF02186 0-17 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 01/14/02 LF02187 0-18 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 01/14/02 LF02188 0-19 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 01/14/02 LF02189 MPHS-20 703 Air <7.0 <0.004 0 0 <8.75 <0.0048 01/14/02 LF02190 Lot Blank 0 Air <7.0 n/a NA<” NA<^’ NA*^ na” 01/14/02 LF02191 Trip Blank 0 Air <7.0 n/a NA*” NA*^’ NA*’* NA<^'

Key: * Sample volume (liters) is below recommended limit for the TEM method: volume is based on pump reading ** Structure (S) is roughly equivalent to fiber (f) *** Chrysotile **** Extremely low sample volume collected

NA*’’ - Not analyzed due to overloading of particulates NA*^’ - Not analyzed for TEM NA*’’ - Not analyzed for PCM or TEM due to wet filter n/a - Not applicable NC - Sample not collected o NS - Sample not submitted A k; I NIOSH 7400: Fiber Analysis of Air samples via NIOSH 7400, Revision 3, Issue 2, 8/15/94 Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) EPA 40CFR Part 763 (AHERA) Standard criteria: EPA 40CFR Part 763 (AHERA): 0.01 fiber/cc (PCM), 70 S/mm^ volume 1200 L, for 25 mm filter (TEM) O o I o o to co crc CJi FK-01-14-02-am

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000287303Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →