Ambient Air Sampling Locations NYC / ER (Jan 12) - Particulate Monitoring (Dataram) o Particulate levels noted at two locations (Stations L and R) were below the OSHA TWA. o Instruments operated approximately 6 hours. o Station L values ranged from 9.0 to 145.9 ug/m^ with an average of 33.5 ug/m/ o Station R values ranged from 4.2 to 75.0 ug/m^ with an average of 22.6 ug'mu o Note: Measurements were not taken at Location N due to an equipment malfunction.

NYC / ER (Jan 13) - Particulate Monitoring (Dataram)

o Monitoring of particulate levels at three locations (Stations L, N, R) was not conducted due to the weather conditions.

NYC / ER (Jan 14) - Particulate Monitoring (Dataram) o Particulate levels noted at three locations (Stations L, N, R) were below the OSHA TWA. o Instruments operated approximately 6 hours. o Station L values ranged from 8.8 to 87.6 ug/m’ with an average of 18.3 ug/m\ o Station R values ranged from 9.8 to 94.9 ug/m’ with an average of 18.7 ug/m\ o Station N values ranged from 6.7 to 390.0 ug/m’with an average of 14.9 ug/m /

NYC / ER (Jan 12) - Volatile Organics (Mobile Laboratory) o Benzene exceeded the OSHA TWA PEL (1 ppm) at one location (North Tower) on the debris pile in the plume at ground level. o Benzene was not detected above the detection limit (20 ppbv) in 3 of the 4 locations monitored (Washing Tent, Austin Tobin Plaza, and South Tower), including in the debris area at ground level. NYC / ER (Jan 14) - Volatile Organics (Mobile Laboratory) o Volatile organic compounds were not detected above the detection limit (20 ppbv) in any of the four samples collected (Washing Tent, Austin Tobin Plaza, North Tower, and South Tower), including in the debris area at ground level.

Direct Reading Instruments

NYC / ER (Jan 12) o Low levels of carbon monoxide noted at nearly all stations during both monitoring periods. o Otherwise, nothing of significance reported.

NYC / ER (Jan 14) o Low levels of carbon monoxide noted at nearly all stations during the afternoon

CITY_21MC100_002417041

NYC-WTC_000287293

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000287293Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000318163

Air sampling results for asbestos at NYC/ER; most samples below standard, some with low volumes or not collected.

Similar indexed content

NYC-WTC_000321253

Jan 11–12 2002 asbestos sampling; access issues for Location T; low sample volumes noted.

Similar indexed content

Compare copies and versions →