EPA November 9, 2001 Environmental Monitoring Summary

Machine-extracted title · confidence 28%

Daily summary of environmental monitoring data collected from World Trade Center site and vicinity.

NYC-WTC_000287073–000287075
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

WTC Enviromental Monitoring: Novetnber 8, 2001 wys!wyg://6/b,ttp;//v»"ww.eria.gov/epahome/wtc/epa-oshal 10801 .htn

VOCs - Sampling for VOCs was conducted on November 6 and November 7 at five locations in the direct area of the debris pile at ground zero. To protect workers at the work site, EPA takes grab samples of VOCs where smoke plumes have been sighted. The results are snapshots of the levels at a moment in time. OSHA's protective standards set a permissible exposure limit (PEL) averaged over an 8-hour day. Six of the ten samples taken on November 6 and 7th at North Park Pier, Austin Tobin Plaza, and the EPA Wash Tent did not find any benzene levels above the detection limit of 20 parts per billion by volume (ppbv). On November 7. benzene exceeded the OSHA PEL of 1 part per million (ppm) in two samples taken from the North Tower and South Tower debris piles. Chlorodifluoromethane (Freon-22) was not found in any samples above the detection limit of 20 ppbv.

Dioxin - Ten samples were collected on October 18 and analyzed for dioxin/furans. Four of the samples (Locations B - Church & Dey, 3A - between World Trade Center buildings 4 & 5, Cl - Liberty and Broadway and D - Greenwich and Albany) showed results above the level at which EPA would take some type of action to reduce people's exposure. This action guideline is based on a 30-year exposure. However, none of the samples were above the EPA action guideline adjusted to a one-year exposure. These levels do not pose a short-term health affect but should be monitored if they persist for a long period of time.

PM 2.5 - Monitoring for fine particulate matter (particles less than 2.5 micrometers in diameter) was conducted on November 6 at Pace University, Borough of Manhattan Community College, and the Coast Guard building in Battery Park. All 24-hour average values were below the National Ambient Air Quality Standard (NAAQS) of 65 ug/m3 for all stations. These results were also less than 40 ug/m3, a level on the EPA Air Quality Index indicating that air quality is unhealthy for sensitive populations (e.g., those with respiratory illnesses).

Particulate Monitoring - EPA used portable monitors to collect samples on November 7 in the following locations: L (north east side of Stuyvesant High School); N (south side of Pier 25); and R (north west side of Stuyvesant High School). Ail readings were below the OSHA time-weighted permissible exposure limit for particulates.

Direct Air Readings - Direct readings taken on November 8 and 7th in and around ground zero showed no levels of significance. No readings were noted above the carbon monoxide NAAQS 8-hour average of 9 ppm.

PATH Train Water Removal - EPA collected samples from the water pumped from the PATH train tunnels on October 3, October 10 and October 26. Samples were analyzed for a variety of substances including metals, VOCs, PCBs, asbestos and dioxin. All of the results for samples collected on October 3 and October 10 were below levels of concern with the exception of zinc, which was detected on October 10 at a level that exceeded marine water quality criteria. Results for PATH samples collected on October 26 identified chlorodifluoromethane (Freon-22) and dichlorodifluoromethane (Freon-12) in the water. The concentrations of all other VOCs were consistent with previous results.

Latest Available Daiiy Environmentai Monitoring Summary

Resources on the World Wide Web:

US Department of Labor's Occupational Safety and Health Administration

New York City Department of Health US Department of Health and Human Services New York State Emergency Management Office

2 of 3 ! 1/13/2001 2:22 PM

CITY_21MC100_003923171

NYC-WTC_000287074

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000287074Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000287070

Daily summary describing EPA and partners’ sampling of air, dust, water near World Trade Center.

Similar indexed content

NYC-WTC_000287076

Daily environmental monitoring summary for WTC site and surrounding area, November 7, 2001.

Similar indexed content

Compare copies and versions →