NYC 9/11 Public Portal Document
WTC Environmental Monitoring: Latest Summary Page 1 of 3
O'*
ElPA tespooDS© to S©[ptemb©ir HI
Contact Us Search: I j Advanced Search
I
Response to 9-11 > Monitoring Summaries
Monitoring Summaries
Monitoring Data Daily Environmental Monitoring Summary
Frequently Asked
Questions Thursday, January 3, 2002
Pictures
EPA Press Releases The U.S. Environmental Protection Agency (EPA) and other federal, state and local
How You Can Help agencies have collected extensive environmental monitoring data from the World
Trade Center site and nearby areas in Manhattan, Brooklyn and New Jersey. Since
September 11, EPA has taken samples of the air, dust, water, river sediments and
drinking water and analyzed them for the presence of pollutants that might pose a
health risk to response workers at the World Trade Center site and the public. The
samples are evaluated against a variety of benchmarks, standards and guidelines
established to protect public health under various conditions. EPA is collecting data
from more than 20 fixed air monitors in and around ground zero and additional
monitors in the Bronx, Brooklyn, Queens and Staten Island. The Agency is also using
portable sampling equipment to collect data from a range of locations.
Results as of 3:00 p.m. on 1/3
Air: Fixed Monitors in New York:
Asbestos - EPA analyzed 41 samples taken in and around ground zero on December
24 and 25. In addition, EPA sampled for asbestos at two lower Manhattan locations
from December 25 through 28. All samples showed results less than 70 structures per
square millimeter, which is the Asbestos Hazard Emergency Response Act (AHERA)
standard for allowing children to re-enter school buildings after asbestos removal
activities. This brings the total number of air samples collected and analyzed for lower
Manhattan to 4,074, with 29 samples above the standard (27 of these were collected
prior to September 30, one was collected on October 9 and the other on November 27).
Air: Fixed Monitors outside lower Manhattan:
Asbestos - Samples were collected from additional asbestos monitors at Public School
154 (33 East 135th St., Bronx), Intermediate School 143 (511 W. 182nd St.,
Manhattan), P.S. 274 (800 Bushwick Ave, Brooklyn), P.S. 44 (80 Maple Parkway,
Staten Island) and P.S. 199 (3290 48th St., Queens) from December 25 through 28.
None showed exceedances of the AHERA re-entry standard.
Staten Island Landfill:
Air (Particulates) - EPA used portable monitors to collect samples of particulates on
December 31 at the Staten Island Landfill. One station of three continued to show
increased readings.
Ambient Air Samples:
Particulate Monitoring - EPA used portable monitors to collect samples on January 2
in the following locations: L (north east side of Stuyvesant High School); N (south side
of Pier 25); and R (north west side of Stuyvesant High School). All readings were below
the OSHA time-weighted permissible exposure limit for particulates.
VOCs - Sampling for volatile organic compounds (VOCs) was conducted on January 2
in the direct area of the debris pile at ground zero. To protect workers at the work site,
EPA takes grab samples of VOCs where smoke plumes have been sighted. The
results are snapshots of the levels at a moment in time. OSHA’s protective standards
set a permissible exposure limit (PEL) averaged over an 8-hour day. Benzene
http://www.epa.gov/epahome/wtc/data_summary.htm 1/6/2002