Airborne asbestos TEM analysis, NYC DEP 11/18/02

Machine-extracted title · confidence 24%

TEM asbestos analysis report for NYC DEP project, AHERA method.

NYC-WTC_000283681
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AIRBORM ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY

CLIENT: WaiTen & Panzer Engineers, P.C. PROJECT: NYC DEP, 150 William Street LABORATORY ID #: T02 11 086 DATE OF REPORT: 11/18/02 ATHENICA ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 11/18/02 ENVIRONMENTAL SERVICES JNC, FILTER TYPE: M C E. EFFECTIVE FILTER AREA (mm^): 385 TO. (716) 784-7490 AVERAGE G.O. AREA (mm^): 0.013433 Fax. (718) 784-4085 LABORATORY RESULTS

CLIENT # LAB. ID # LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPIIIB. (It) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (struct./cm’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm^) (struc./cm^) CONC. STRUCT. STRUCT. SPECIFY (str./mm’) 0.5SS<Spin S>5.0|.im 01 T02-11- West side of set 1506 4 0.0537 0.0048 <0.0048 <18.61 NA NA NA NA 086-4140 back 02 T02-11- Entrance to set back 1506 4 0.0537 0.0048 <0.0048 <18.61 NA NA NA NA 086-4141 03 T02-11- Set back window 1506 4 0.0537 0.0048 <0.0048 <18.61 NA NA NA NA 086-4142 04 T02-11- East side of set back 1506 4 0.0537 0.0048 <0.0048 <18.61 NA NA NA NA 086-4143 05 T02-11- Entrance to east set 1506 4 0.0537 0.0048 <0.0048 <18.61 NA NA NA NA 086-4144 back

ANALYST LABORATORY DIRECTOR E. Sioukri Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955

o Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within ’.his time frame for a true duplicate analysis. K I If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is supplied solely for the convenience of the client. S The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. Test reports may not be reproduced o except in full and with prior approval of AES Inc. o The liability of Athenica Environmental Services Inc. with respect to the seivices charged, shall in no event exceed the amount of the invoice. o I o o

CT

O CT

NYC-WTC_000283681

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000283681Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Airborne asbestos TEM report, NYC DEP site, Sep 2002

NYC-WTC_000206372

Final laboratory report detailing transmission electron microscopy results for airborne asbestos analysis conducted at a New York City Department of Environmental Protection site.

Similar indexed content

Compare copies and versions →