Airborne asbestos analysis, TEM AHERA, 2002

Machine-extracted title · confidence 48%

TEM AHERA asbestos analysis report for NYC DEP project; includes lab ID and date.

NYC-WTC_000283622
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY

CLIENT: Warren & Panzer Engineers, P.C. PROJECT: NYC DEP, 136 William Street LABORATORY ID #: T02 11 087 DATE OF REPORT: 11/19/02 ATHENICA ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS; 11/19/02 EKv'lRONMENTAt SERVICES INC. FILTER TYPE: M C E. EFFECTIVE FILTER AREA linin’): 385 Tel. 1718) 784-7490 AVERAGE G.O. AREA (mm^): 0.013433 Fax. (718) 784-4085 LABORATORY RESULTS

CLIENT # LAB. ID # LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMFHIB. (It) ANAL ANALY SENSITTV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (striict./cm’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm^) (struc./cm^) CONC. STRUCT. STRUCT. SPECIFY (str./mm^) 0.5<S<5pm S>5.0piii 01 T02-11- Exit to roof 1680 4 0.0537 0.0043 <0.0043 <18.61 NA NA~ NA NA 087-4145 02 T02-11- IWA right side of 1680 4 0.0537 0.0043 <0.0043 <18.61 NA NA NA NA 087-4146 WA 03 T02-11- IWA r middle of 1680 4 0.0537 0.0043 <0.0043 <18.61 NA NA NA NA 087-4147 WA 04 T02-11- IWA 2"‘‘middle of 1680 4 0.0537 0.0043 <0.0043 <18.61 NA NA NA NA 087-4148 WA 05 T02-11- IWA north side of 1680 4 0.0537 0.0043 <0.0043 <18.61 NA NA NA NA 087-4149 WA

6^ A/ ANALYST LABORATORY DIRECTOR E. Sioukri Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955 o Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. Air sampling cassettes will be stored for sixty (60) days. AEiS Inc., should be notified within this time frame for a true duplicate analysis. K I If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is supplied solely for the convenience of the client. S The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. Test reports may not be reproduced O except in full and with prior approval of AES Inc. o The liability of Athenica Environmental Services Inc. with respect to the seivices charged, shall in no event exceed the amount of the invoice. o I o o

CT

co

NYC-WTC_000283622

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000283622Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →