AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY CLIENT: Warren & Panzer Engineers, P.C. PROJECT: NYC DEP, 130 William Street LABORATORY ID #: T02 10-186 DATE OF REPORT: 10/30/02 ATHENICA ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 10/30/02 ENVIRONMENTAL SERVICES incFILTER TYPE: M.C.E. EFFECTIVE FILTER AREA (mm^): 385 TeL (718) 784-7490 AVERAGE G.O. AREA 0.013433 Fax. (718) 784-1085 LABORATORY RESULTS

CLIENT # LAB. ID # LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. (It) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (stract./cm’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm’) (struc./cm’) CONC. STRUCT. STRUCT. SPECIFY (str./mm’) 0.5<S<5pm S>S.0pm 01 IWA T02-10- IWA on roof center 1620 4 0.0537 0.0044 <0.0044 <18.61 NA NA“ NA NA 186-3634 of work area 02IWA T02-10- IWA on roof south 1620 4 0.0537 0.0044 <0.0044 <18.61 NA NA NA NA 186-3635 section of work area 03IWA T02-10- IWA on roof north 1620 4 0.0537 0,0044 <0.0044 <18.61 NA NA NA NA 186-3636 section of work area 04OWA T02-10- OWA on hallway 1620 4 0.0537 0.0044 <0.0044 <18.61 NA NA NA NA 186-3637 leading to roof 4ft. of door entrance 05OWA T02-10- OWA in the clean 1620 4 0.0537 0.0044 <0.0044 <18.61 NA NA NA NA 186-3638 room of per. decon.

ANALYST LABORATORY DIRECTOR E. Sioukri Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955 o H K Athenica Environmental Setvices inc. (AES), is responsible only for information pertaining to samples taken by its employees. I Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for a true duplicate analysis. to If ARS Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is S supplied solely for the convenience of the client. o rhe report relates only to items tested, flis report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. Test reports may not be reproduced o except in full and with prior approval of AES Inc. o I The liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice. o o to cn o

CT

NYC-WTC_000283563

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000283563Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →