Airborne asbestos analysis by TEM, NYC DEP, 2002

Machine-extracted title · confidence 41%

TEM asbestos analysis report for NYC DEP project; client Warren & [name], date 10/10/02.

NYC-WTC_000283122
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

Z ■< Z ■<

o o g AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY co O I CLIENT: Warren & Panzer Engineers, P.C. PROJECT: NYC DEP, 12 Platt Street “0 o c o A -TLitTMiz- A LABORATORY ID #: T02 10-094 DATE OF REPORT: 10/15/02 CT o ro oo ATHENICA ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 10/15/02 o' Ca3 EffviRONMENTAL SERVICES iNfjLTER TYPE: M.C.E. EFFECTIVE FILTER AREA (mm’): 385 "0 o ro Tel. (718) 78+-7490 AVERAGE G.O. AREA 0.013838 ro CD Fax. (718) 7&4-M)85 0 LABORATORY RESULTS o o c CLIENT# LAB. ID # LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. 3 o (It) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST 3

YZED ZED (struct./cm'l AIR CONC. FILTER FOR FOR CHRYS. TYPE (mmh (struc./cm’) CONC. STRUCT. STRUCT. SPECIFY (str./mm“) 0.5<S<5|Tm S>5.0pm ID 01 T02-10- IWA r right side of 1800 4 0.0554 0.0039 <0.0039 <18.07 NA xTT” NA NA 094-3156 WA ID 02 T02-10- IWA 2’ right side 1800 4 0.0554 0.0039 0.0039 18.07 <0.0039 0.0039 Chrys. NA 094-3157 ofWA ID 04 T02-10- IWA middle of WA 1800 4 0.0554 0.0039 0.0077 36.13 <0.0039 0.0077 Chrys. NA 094-3158 ID 05 T02-10- IWA left side of 1800 4 0.0554 0.0039 <0.0039 <18.07 NA NA NA NA 094-3159 WA ID 09 T02-10- IWA 3'^“ right side 1800 4 0.0554 0.0039 <0.0039 <18.07 NA NA NA NA 094-3160 ofWA

ANALYST LABORATORY DIRECTOR E. Sioukri Spiro Dongaris

o LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955

Athenica Environmental Services Inc, (AES), is responsible only for information pertaining to samples taken by its employees. to Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for a true duplicate analysis. If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is S supplied solely for the convenience of the client. o rhe report relates only to items tested. This report must not be used to claim product endorsement by NVI.AP oi any other agency of the U.S. Government. Test reports may not be reproduced o o except in full and with prior approval of AES Inc I The liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice. o o

CTh

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000283122Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →