Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
Z
z
o
o
co
AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY
o
o CLIENT: Warren & Panzer Engineers, P.C, PROJECT: NYC DEP, 45 Park place c
o CT
ro ATHENICA laboratory id#: T02-10-168 DATE OF REPORT: 10/26/02
oo o'
Ca3 INC. ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 10/26/02
o "0
oo EFFECTIVE FILTER AREA (mm’): 385 o
FILTER TYPE: M C E
G.O. area (mm’): 0.013433 9L
O
o
LABORATORY RESULTS o
c
3
ASBEST. AMPHIB.
o
CLIENT # LAB. ID # LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR 3
(It) ANAL AN ALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST
YZED ZED (struct./cm’) AIR CONC. FILTER FOR FOR CHRYS. TYPE
(mm’) (struc./cm’) CONC. STRUCT. STRUCT. SPECIFY
(str./mm’) 0.5sS<5nm S>5.0p.m
01 T02-10- Inside work area 1680 4 0.0537 0.0043 <0.0043 <18.61 NA NF“ NA NA
168-3543 south
02 T02-10- Inside work area 1680 4 0.0537 0.0043 <0.0043 <18.61 NA NA NA NA •
168-3544 east
03 T02-10- Inside work area 1680 4 0.0537 0.0043 <0.0043 <18.61 NA NA NA NA
168-3545 west
04 T02-10- Inside work area 1680 4 0.0537 0.0043 <0.0043 <18.61 NA NA NA NA
168-3546 center
05 T02-10- Inside work area 1680 4 0.0S37 0.0043 <0.0043 <18.61 NA NA. NA NA
168-3547 north
ANALYST LABORATORY DIRECTOR
E. Sioukri Spiro Dongaris
a
LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955
H
Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees.
Air sampling cassettes will be stored for sixty (60) days AES Inc., should be notified within this time frame for a true duplicate analysis.
If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is
O
supplied solely for the convenience of the client.
O The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government Test reports may not be reproduced
I except in full and with prior approval of AES Inc.
o
o The liability of Athenica Environmental Services Inc. with respect to the seivices charged, shall in no event exceed the amount of the invoice
CT)
CD
CO
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000283084Source: NYC Law Department, mirrored locally