Airborne asbestos TEM report, NYC DEP

Machine-extracted title · confidence 46%

TEM asbestos analysis report for NYC DEP project, Feb 2003.

NYC-WTC_000282881
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY CLIENT: Warren & Panzer Engineers. P. C PROJECT: NYC DEP, 15 Park Row ATHENICA LABORATORY ID #; T03-02-010 DATE OF REPORT: 02 0303 ENVIRONMENTAL SERVICES INC. ANALYT. METHODOLOGY: AHFRA DATE OF ANALYSIS: 02/0303 Tel (718) 784-7490 FILTER TYPE: M C E. EFFECTIVE FILTER AREA 385 Fax (718) 784-4085 AVERAGE G.O. AREA (mm^); 0.012820

LABORATORY RFSI I I S

CLIENT# LAB. ID # LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBF.ST, AMPHIB. (It) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (struct./cm’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm’) (struc./cm’) CONC. STRUCT. STRUCT. SPECIFY (str./mm’) 0.5<S<5nm S>5.0|j.m 01 T03-02- Decon 1700 4 0.0513 0.0044 <0.0044 <19.50 NA NA NA NA 010-166 02 T03-02- Left side of set back 1700 4 0.0513 00044 <0.0044 <19.50 NA NA NA NA 010-167 03 T03-02- Center of set back 1700 4 0.0513 0.0044 <0.0044 <19.50 NA NA NA NA 010-168 04 T03-02- Right side of set 1710 4 0.0513 0.0044 <0.0044 <19.50 NA NA NA NA 010-169 back 05 T03-02- Corridor 1690 4 0.0513 0.0044 <0.0044 <19.50 NA NA NA NA 010-170

ANALYST LABORATORY DIRECTOR E. Sioukri Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955

Athenica Environmental Services Inc. (ATS), is responsible only for information pertaining to samples taken by its employees. Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for a true duplicate analysis. o If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client Under these circumstances, the air concentration data is supplied solely for the convenience of the client. The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. Test reports may not be reproduced I except in full and with prior approval of AES Inc. The liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice S n o o I o o

cn

NYC-WTC_000282881

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000282881Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →