Asbestos Final-clearance air sample collection and analysis
(1) Asbestos air sample collection and analysis
a. PCM, Phase Contrast Microscopy and TEM, (Transmissio.n Electron
Microscopy) samples were collected by GPS, a Licensed asbestos
consulting firm.
b. AU post samples were required to be below 0.01 f/cc (PCM) and less
than 70 Structures/mm2 for (TEM). If one sample was at or above
these limits then the area was re-cleaned until all sample results were
below these limits.
Tony, approximately 62,000 PCM and 31,000 TEM asbestos samples have been collected and
analyzed to date. Post Sampling for Phase Ill is completed for the upper fresh air bank, floors 17
through the Penthouse and for the lower fresh air bank, floors C3 through 16.