Summary of Transmission Eketron Microscopy (TEM) Results for Asbestos (air)
03-2744; NYC DEP, J14 Liberty Street; NY, NY/DURINGS 3
Structure Structure
Air Area * Analytical Asbestos Structures Detected Density Concentration Type
SciLab
Sampled
Client
Sample #
Dilution Filtered Analyzed Sensitivity
Factor (lOm) (sq.mm.) (stnic/ccair) 0.5-5.0
(Microns)
>5.0 Total
(struc/sq. mni.)
>5.0 Total
(stnic/fx air)
>5.0 Total
of
Asbestos
s
01 009705 3600 .12 0.0009 0.0 0.0 00 <8.3 <8.3 <0.0009 <0.0009 NSD
During/Eatiance to Bldg 114 Liberty Slicet (OWA)
cn
02 009706 3600 .12 0.0009 1.0 2.0 3.0 16.7 250 0.0018 00027 chrysotile 1,0
During/lnside of Bldg. Nocthem Side arrtphibule ixi
‘jj
03 009707 3600 12 0.0009 0.0 00 0.0 <8.3 <8.3 <00009 <0.0009 NSD
Oirring/Entrance to Bldg. (Rear) Cedar Street (OWA)
04 009708 3600 ,12 0.0009 3.0 00 3.0 <8.3 25.0 <0.0009 0.0027 dirysolite
Ditrittg/lnside of Bldg, Soulhem Side
05 009709 3643 .12 0-0009 20 0.0 2.0 <8.3 167 <0.0009 0.0C18 chrysotile
During/insiile of Personal Oecon Clean Room
O
I
w
z
C)
o
m
o
20
00
'o
>
z
z
>
c >
00 • ctmccntratioo represented by the detection of I stnicture m
not analyzed
o
o
o
NSD: No Asbestos Structures Detected Reviewed By: ; Analyzed By;
Mark Peysakhov
Date: 4/1/03
5'■Xi
o
NVLAP#: 200546-0