Dust wipe analysis, 114 Liberty Street, 2003

Machine-extracted title · confidence 57%

Summary of lead/dust wipe analysis from 114 Liberty Street site samples.

NYC-WTC_000282569–000282576
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

JLC ENVIRONMENTAL CONSULTANTS. INC. 200 Park Avenue South, Suite 1001. New York, New York 10003 Phone; (212) 420-8119 Pax; (212) 420-6092 Project No.: 03.2744 New York CIlyD.E.P, ELAP Lab Code; 11026 Analyte; LEAD/WIPE 80-17 Junction Blvd. NIOSH and AIWA Lab Code; 100273 Dale Collected 3/29/2003 Flushing, NY 11373 NVLAP Lab Code; 101953 Date Reoelved: 3/30/2003 Date Analyzed: 3/30/2003 Batch#; 0303L410

Site; 114 Liberty Street, 12th Floor, New York, NY

SUMMARY OF ANALYTICAL RESULTS - DUST WIPE

Sample# Description/ Location Area in Inches Lead Lab# (LxW) Concentration CHent'a Sample (ug/n2) BECSSBBBXBE sas

1 Lead Wipe/11th Floor/ Upstairs/ Kitchen/ Floor 12k12 12,0 3412 01

2 Lead Wipe/11th Floor/ Upstairs/ Kitchen/ Counter Top 12x12 <9 3413 02

3 Lead Wipe/ 11th F/oor/ Upstairs/ Kitchen/ East Wall/ 12x12 <9 3414 Lower Right 03

4 Lead Wipe/ 11th Floor/ Downstairs/ Kitchen/ Floor 12x12 <9 3415 04

Sample Analysis By; Atomic Absorption Spectrometry (AAS) using an alr-scetyane flame with background correetton. Method of Sample Preparation and Analvaig All eamples were prepared end analyzed In accordance with the HUD "Guidelines for the Evaluation and Control of Lead Based Paint Hazardous in Housing* Appendix 14.2 and ths Environmental Protsctlon Agency Method EPA SW848-3050/7420,

Gulam Machhiwala CdlBcted By; Peter Koslowiky Laboratory Director Analyzed By: Madell Collins

Minimum DeeteotlOfi Limit « <20 ug/fB HUD "Guldstines tor the Evaluation and Control of Lead-Baaed Paint Hazardoua In Housing* 06/95; define the clearance standards, based on wipe sampiirrg are: *40 ug/H2 fw floors; *250 ug/ft2 for interior window sillsi *400 ug/fB for window and exterior concrete or olher rough

Page 1 of 8

11A 'd 9SrON ItfiNdWNOdlANe 3K NdOrv ecore ’dcV CITY_DEP_WORBY_CANNATA_SUBP_000006038

NYC-WTC_000282569

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000282569Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →